CHANGING OPERATING PARAMETERS
Press any of the OK, ESC or arrow buttons. The system will now be ready to change the operating parameters.
The active field flashes.
It is possible to move from one option to another using the buttons
by pressing the button
It is possible to increase/decrease the values or enable/disable the functions for all options by pressing the
,
, to move from one field to the next using the buttons
buttons
pressing the button
The parameters that can be changed by the user are:
- fans operating speed in percentage: can have value from 0%
to 100%.
If the current value is > 10%, each press of the button will
correspond to an increase/decrease of 10.
Note: this parameter cannot be changed in WINTER AUTO
mode.
- direction of fan rotation: can have a VENT value (air directed
downwards), or a REV value (air directed upwards).
Note: this parameter cannot be changed in SUMMER mode.
- mode:
SUMMER (summer mode): air is directed downwards; the
user can change the speed.
WINTER MAN (manual winter mode): the user can change
the speed and direction of rotation.
WINTER AUTO (automatic winter mode): the user can
change the direction of rotation. The speed depends on the
temperatures detected by the probes (see details in the
Configuration Menu paragraph, option SET DT ALLOWED).
Note
If the control unit and the fan coil are connected to two different lines and power is cut off from the control unit,
the fans cannot be controlled and power must be disconnected also from the fans to switch them off.
26
.
. The active field flashes.
,
and to modify the desired option
, and to confirm choices by
,
90 %
SPEED
WINTER AUTO
90 %
SPEED
WINTER AUTO
WINTER AUTO
90 %
SPEED
VENT
10
VENT
10
VENT
10