Technical features
Current Range:
Output Sensitivity:
Load Impedance:
Output Connection:
Accuracy (at +25°C):
Linearity (from 10 % to 100 % of range):
Frequency Range:
Phase Error:
Position Sensitivity:
Noise:
6.3.
Electronic mechanical features
Dimensions:
Weight:
Material:
Flame retardant ratio:
6.4.
Measuring head mechanical features
Maximum conductor diameter:
Head length:
Flexible head cable length:
Weight:
Material:
Flame retardant ratio:
6.5.
Power supply
Battery type:
Battery life:
6.6.
Environment
Working and storage temperature:
Gain change
Working and storage humidity:
6.7.
EMC
This instrument has been designed in compliance with the EMC standards in force and its
compatibility has been tested for EN61326-2-2:2006
EN61010-1:2001 ; EN61010-2-032 :2002
EN61010-031 :2002
Double insulated
2
CAT III 1000V∼ to ground
300 / 3000A∼
3.333 / 0.3333mV∼ per A∼
100kΩ minimum
3 x 0.5 m cable with 3 way connector
±1.0% rdg ± 0.1A (45 – 65 Hz)
±0.2 % rdg
from 10Hz to 20kHz (-3dB)
<±1° (45 - 65 Hz)
± 2 % of rdg
2mV
110 (L) x 65 (W) x 23 (H) mm
190g
ARNITE T06-200SNF, IP40
UL94-VO
174 mm
610mm
2m
180g
Alcryn 2070 NC, IP65
UL94-VO
2x1.5V AA MN 1500 LR6 alkaline batteries
about 1000 hours
–20 °C to +85 °C
± 0.08% of rdg per °C
15% to 85% RH
EN - 8