_______________________________________________________________ 4-CHANNEL SCOPE MODULE
3.0 -
USE OF THE 4-CHANNEL SCOPE
•
Select 4-CHANNEL SCOPE from the initial page.
a
b
a.
Channels enabling: this function is used to enable/disable any channel being
sampled singularly.
b.
Help: this function allows rapid access the oscilloscope help menu.
Press F1 to display the initial presetting selection page.
Press F2 (if active) to display a sample image of the selected signal.
Press F3 (if active) to display the signal characteristics.
Press F4 for auto set: this function is used to detect the analysed wave form
and to set the voltage scale (Volt) and the time scale (time/div) in automatic
mode.
Press F5 to quit.
c.
Setup:
this
(see f, g, h, i functions).
d.
Measure: this function is used to measure the time and voltage differences
between two points on the wave form.
e.
Managing: this function is used to save and recall sampled wave forms.
OPERATING INSTRUCTIONS