6.8 Operation Parameter
This menu is for installer or service engineer reviewing the operation
parameter.
At home page, go to ''MENU'' > ''OPERATION PARAMETER''.
Press ''OK''. There are five pages for the operating parameter as
following. Use '' '' '' '' to scroll.
OPERATION PARAMETER
OPERATE MODE
COMPRESSOR CURRENT
COMPRESSOR FREQUNCY
COMP.RUN TIME1
COMP.RUN TIME2
COMP.RUN TIME3
SCROLL
OPERATION PARAMETER
COMP.RUN TIME4
EXPANSION VALUE
FAN SPEED
BACKUP HEATER1 CURRENT
BACKUP HEATER2 CURRENT
T1 LEAVING WATER TEMP.1
SCROLL
OPERATION PARAMETER
T1B LEAVING WATER TEMP.2
T2
PLATE F-OUT TEMP.
T2B PLATE F-IN TEMP.
T3 OUTDOOR EXCHANGE TEMP.
T4 OUTDOOR AIR TEMP.
T5 OUTDOOR AIR TEMP.
SCROLL
OPERATION PARAMETER
Ta Room temp
Th COMP.SUCTION TEMP.
Tp
COMP. DISCHARGE TEMP.
Tw-0 PLATE W-OUTLET TEMP.
Tw-I PLATE W-INLET TEMP.
P1 COMP. PRESSURE1
SCROLL
OPERATION PARAMETER
P2 COMP. PRESSURE2
POWER CONSUMPTION
SCROLL
COOL
12A
24Hz
54MIN
65MIN
10MIN
1/5
1000HOUR
240P
600 R/MIN
0 A
0 A
25°C
2/5
25°C
30°C
45°C
-7°C
-7°C
-7°C
3/5
25°C
25°C
25°C
25°C
25°C
200kPa
4/5
--kPa
OKWH
5/5
INFORMATION
The power consumption parameter is preparatory.
if some parameter is not be activated in the system, the parameter
will show "--"
6.9 For Serviceman
6.9.1 About For Serviceman
FOR SERVICEMAN is used for installater and service engineer.
Setting the composition of equipment.
Setting the parameters.
6.9.2 How To Go To FOR SERVICEMAN
Go to ''MENU'' > ''FOR SERVICEMAN''. Press ''OK''.
FOR SERVICEMAN
Please input the password:
2
ENTER
ADJUST
OK
The FOR SERVICEMAN is used for installer or service engineer.
It is NOT instended the home owener alters setting with this menu.
It is for this reason password protection is requierd to prevent
unanthorised access to the service settings.
The password is 234.
6.9.3 How To Exit FOR SERVICEMAN
If you have set all the parameter.
Press ''BACK'', the following page will be appear
FOR SERVICEMAN
Do you want to exit the for
serviceman?
NO
CONFIRM
OK
Select ''YES'' and press ''OK'' to exit the FOR SERVICEMAN.
After exiting the FOR SERVICEMAN, the unit will be turned off.
42
3 4
SCROLL
YES
SCROLL