Electrical Connections - GIESSE RACK MAX 650 Manual De Uso

Actuador de cremallera
Ocultar thumbs Ver también para RACK MAX 650:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
Configuration
a
b
c
d
e
f
DISTANCE BETWEEN CENTRES OF THE CONNECTION BARS
Code
4010009
Connection bar 1000 mm length
4010010
Connection bar 1500 mm length
4010011
Connection bar 2000 mm length
4010011
Connection bar 2500 mm length
Assemble as follows:
A. Mark the assembly distance between centres for the two actuators out onto the
frame in accordance with the measurements in the above table.
B. Place the support brackets of the actuator into position, mark
out the holes for drilling, drill the frame and mount the
brackets (see "Assembly for outward opening windows" for
details).
C. Place the front brackets into position, mark out the holes for
drilling, drill the frame and mount the front brackets (see
"Assembly for outward opening windows" for details).
D. Mount the actuators (see "Assembly for outward opening
windows" for details) – see Fig.7.
E. Mount the connection bar as follows:
• Insert the connection bar first into one of the actuators, and
then into the second actuator. Make sure the bar protrudes
at least 2 mm from each actuator (Fig. 7 bis).
• Mount and screw the M8x14 mm flat headed screw
(provided with connection bar), into the two ends of the bar
to prevent the bar from slipping out.

9. Electrical connections

The actuator comes with a 2 m long circa (±5%) lead which has been calculated in
accordance with safety rules.
In the event that the distance between the actuator and the control button should
exceed this length, the cable should be extended.
See table on page 8 for conductor section indications. For harness, please follow the
these diagrams.
No. of motors
(M)
1
1
1
2
2
2
Description
No. of drive
No. of thrust
units (R)
1
2
2
0
1
2
Length of bar
36
Total force
points
2
3
3
2
3
4
distance between
(mm)
centres (mm)
1.035
1.535
2.035
2.535
600N
600N
600N
1000N
1000N
1000N
"D"
1.000
1.500
2.000
2.500
Fig. 7
Fig. 7 bis

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rackmax 650 230v

Tabla de contenido