Horizontal Unit Heater 10KW - 240V - 1 or 3 Phase
How to select a thermostat setting:
Using the built-in temperature controller (built-in
thermostat):
Note: The selector switch must be at the "INSIDE
THERMOSTAT" position.
1.Ambient temperature is regulated by adjusting the built-in
thermostat to a desired position.
2.Allow the unit to operate and warm up the room.
3.When the desired temperature is reached, turn the control
knob counterclockwise until the heater turns off. This is the ideal
setting.
4.The heater will start automatically when the room temperature
drops below this set point, and will turn off when the set point is
reached.
Using an external temperature controller (a wall
thermostat):
Note: The selector switch must be at the "WALL
THERMOSTAT" position.
1.To use an external temperature controller (a wall thermostat),
follow the installation instruction to connect the wall thermostat
first.
2.Press the selector switch to "WALL THERMOSTAT" position.
Now wall thermostat is selected and the built-in thermostat is
being disconnected.
3.Ambient temperature is regulated by adjusting the wall
thermostat to a desired position.
4.Allow the unit to operate and warm up the room.
5.When the desired temperature is reached, turn the control
knob counterclockwise until the heater turns off. This is the ideal
setting.
6.The heater will start automatically when the room temperature
drops below this set point, and will turn off when the set point is
reached.
TROUBLESHOOTING
If your heater fails to operate, please follow these procedures:
This heater is intended to be ceiling or wall mounted. It has thermal cut-off protection. If the thermal cut-off protection trips, turn off
the power and switch off the circuit breaker. The unit should reset automatically after 10 minutes. If the thermal cut-off protection
trips again, consult a certified electrician to determine the reason for overheating.
Problem
Unit is not heating.
Breaker/Fuse has been tripped.
Check & ensure there are no combustible
materials within 0.9 meters (3 feet) surrounding
the heater.
The heater is
during the manufacturing process. It will quickly
producing a burning
evaporate and should not occur again.
smell.
Ensure a minimum clearance of 4.5 inches
(11.5 cm) from both sides and rear of heater to
adjacent walls.
PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HEATER YOURSELF.
DOING SO COULD CAUSE DAMAGE OR PERSONAL INJURY.
Probable Cause
A small amount of oil fell on the heating coil
MAINTENANCE AND CLEANING
There is no user maintenance except regular cleaning as
explained below. All other servicing or maintenance should be
performed by qualified service personnel.
Before any cleaning, make sure that:
1.Disconnect power supply at source. Switch off the circuit
breaker.
2.Wait for 60 minutes to ensure the heating element has cool
down before cleaning.
Regular Cleaning:
1.Do not use cleaning liquid or other chemicals to spray on the
unit.
2.Interior dust can often be removed by using a vacuum cleaner
with a crevice tool attachment.
3.To clean enclosure, use a clean, soft and lightly damp cloth to
gently wipe off the dirt from the surface of the unit. Be sure not
to wet the heating element and the switches. Allow the unit to dry
completely before using it.
Do not allow water to run into the interior of
the heater as this could create a fire or
electric shock hazard and damage the unit.
Turn the heater OFF; Switch off the circuit
breaker. Wait 10 minutes before turning on the
heater.
Check your electrical box to confirm the breaker has
not been blown. This may occur if the receptacle is
shared between other high consumption appliances.
Remove any combustible items from the heater.
Ensure room in which heater is situated is well
ventilated.
Reposition the heater so there is enough space
around the heater to the adjacent walls.
6
User's Manual
Solution