English
The Main and Remote unit
The 4 in 1 Cable Tester consists of a Master unit and detachable
Remote unit. If a short cable is tested, it is not necessary to remove
the remote unit from its docked position on the Main unit. If the two
ends of testing cable are not in the same location, the Remote can
be detached from the Main unit. Once detached, the Remote can be
attached to one end of the cable, and the Main unit attached to the
other end of the cable.
Performing the Test
Once both units are attached to the ends of the cable, simply press
and release the Test Button on the Main unit, the LED indicators
and the "beep" sound indicate the test results. The Numbered LEDs
indicate that a connection exists. If the Short or Cross LEDs are lit,
there is a fault in the cable.
Note: When testing an RJ-45 UTP cable, the S/G LED must not
light. When testing an RJ-45 STP cable, the S/G must light. The 4
in 1 tester is intended to test complete cables. It may not find faults
in cables that are intentionally incomplete. For example, a standard
RJ-45 Ethernet cable is expected to contain 8 conductors. If only 4
conductors are used, the tester may not properly identify the faults.
RJ-11 cables may have 2, 4 or 6 connections. For 2 connection
cables, LED 3 and 4 must light. For 4 connection cables, LED 2, 3,
4 and 5 must light. For 6 connection cables, LED 1, 2, 3, 4, 5 and 6
must light.
Power LED
The Power LED should light whenever the "Test" Button is pressed
and released. It will be on for a minimum of 5 seconds. If the Power
LED does not light, replace the battery.
Low Battery LED
The low Battery LED should not light. If it does, replace the battery.
-
-
3