4.4) ERRORS:
these appear during operation, combined with a beep and flashing
LED Worklights, to notify the operator of procedural or operational errors.
Message
Error description
The pressure release button (5) was
pressed before the control parameters
ERROR
were reached (Force/Pressure).
Abnormal power consumption of the
motor for more than 3 seconds.
001
The tool stops.
002
Output voltage of the pressure trans-
mitter is out of the pre-set range.
002
Failure to reach the set pressure within
003
30 seconds of continuous operation of
003
the machine.
Overcharging of the battery with
004
protection tripping.
004
The tool stops.
Error screens are displayed for about 30 seconds before being reset, but will
display repeatedly in the event of permanent anomalies.
5. CONNECTION TO COMPUTER
The memory card integrated in the tool records operating data from 200.000
cycles for transfer via the USB cable supplied.
To view and manage this data, go to www.cembre.com and register in the
dedicated area, then download the free Cembre software CEM_SWBT01.
Keeping the Firmware of the tool updated, via free of charge download
from here, will optimise the tool's performance.
Solution
Repeat the work cycle and wait for the motor
to stop automatically.
Wait for the display to turn o (60 sec.) or
remove and re-insert the battery, then re-
start the tool.
If the error occurs frequently, contact
Cembre.
Repeat the work cycle; if the error
occurs frequently, contact Cembre.
Repeat the work cycle; if the error
occurs frequently, contact Cembre.
Wait for the display to turn o (60 sec.) or
remove and re-insert the battery, then re-
start the tool.
If the error occurs frequently, contact
Cembre.