4. DISPLAY
The OLED display switches on automatically when the operating or pressure release buttons are
pressed, and o after 60 seconds of non-operation.
The display shows:
- The main operational parameters of the tool processed by the circuit board, such as peak pres-
sure or force reached.
- Information on the condition of the tool, such as the charge level, the battery temperature and
maintenance requirements.
- Any operational or procedural ERRORS.
Use the touch button (8) to navigate through the menu screens to manage INFORMATION AND
SELECTION:
4.1) INFORMATION SCREENS:
appear each time the tool is started and during the entire work cycle.
F
= 60.0 kN
m
Fp = 24.5 kN
F
= 6.75 ton
m
Fp = 2.75 ton
P
= 661 bar
m
Pp = 312 bar
P
= 9587 psi
m
Pp = 4525 psi
BATTERY
1000
-19000
B500
NR 13AJ002
display a pre-determined parameter which will then
Fm: Minimum set force, expressed in kN.
Fp: Peak force reached, expressed in kN,
(screen as factory setting)
Fm: Minimum set force, expressed in US sh. tons.
Fp: Peak force reached, expressed in US sh. tons.
Pm: Minimum set pressure, expressed in bar.
Pp: Peak pressure reached, expressed in bar.
Pm: Minimum set pressure, expressed in psi.
Pp: Peak pressure reached, expressed in in psi.
Battery charge level.
No. of cycles performed.
No. of cycles before scheduled recommended maintenance.
Cembre logo, tool model.
tool serial no.
10