Fig. 1: Connection and installation tank dimensions [mm]
TCM200ZG
A (mm)
25
B (mm)
130
C (mm)
/
D (mm)
/
E (mm)
880
F (mm)
1240
G (mm)
1835
H (mm)
570
I (mm)
585
J1 (mm)
/
J2 (mm)
/
HV
G3/4
IM
/
CV
G3/4
VM
/
TV
G3/4
OTHER HEATING SOURCES - SENSOR INSTALLATION
On the left side of the hot water storage tank are two openings (J1, J2), where the sensors for the control system of the connection of
the hot water tank to other heating sources. The maximum diameter of the probe is 8 mm. The length of the sensor tube is 180 mm.
Insert the sensor into the tube and attach it:
• If the sensor is installed in the top (higher) position, then the thermostat will respond sooner, operating intervals of the circulation
pump will be sorter, difference between water temperature in the hot water storage tank and the heating medium after the
thermostat is switched off; as a result, the amount of hot water in the hot water storage tank will be lower.
• If you install the sensor in the bottom (lower) position, the circulation pump operating intervals will be longer, the difference between
the temperature of the heating medium and the actual water temperature in the hot water storage tank will be lower, and as a result,
the amount of hot water in the hot water storage tank will be greater.
16
TCM201ZG
TCM300ZG
25
25
130
140
218
/
490
/
880
880
1240
1250
1835
1930
570
670
585
685
765
/
1185
/
G3/4
G1
G1
/
G3/4
G3/4
G1
/
G3/4
G1
LEGEND
HV
Cold water inlet (H – blue rosette)
IM
Heat exchanger medium outlet (black rosette)
CV
Circulation pipeline (black rosette)
VM Heat exchanger medium inlet (black rosette)
TV
Hot water outlet (T – red rosette)
J1
Sensor pipe
J2
Sensor pipe
VZ
Air inlet
IZ
Air outlet
TCM306ZG
25
140
245
490
880
1250
1930
670
685
805
1185
G1
G1
G3/4
G1
G1