Operating The Appliance - Gorenje TCM 200 - 300 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONNECTION TO THE POWER SUPPLY NETWORK
Appliance connection requires an electrical outlet suitable for current load specified in the technical information table.
Connecting the appliance to the power supply network must take place in accordance with the standards for electric appliances. To
comply with the national installation regulations, an all poles disconnect switch must be installed between the appliance and the
power supply network.
Fig. 6: Connection to the power supply network

OPERATING THE APPLIANCE

After connecting the appliance to the water and power network and to the hot water storage tank filled with water, it is ready for
operation. Upon connection to the supply voltage, the heat pump switches to standby mode. In the standby mode, the heat pump
maintains a water temperature of 10 °C.
The heat pump heats the water in the range from 10 °C to 65 °C. From 65 °C to 75 °C, the water is heated by an electric heater.
Fig. 7: Control panel
Heat pump on/off
Switch on the heat pump by pressing the
Press and hold (for 3 s) the
20
LEGEND
Heat upon on/off key, water temperature setting
Electric heater on/off key
Display for set/actual water temperature in the hot water storage tank, error indicator
Indicator for electric heater and "TURBO" function operation
key and holding it (for 3 seconds).
key again to switch the heat pump to standby mode.
LEGEND
1
Power cord
2
Electronic module
3
Thermal cut-out
4
Compressor
5
Fan
6
Electrical heater
T1
Temperature sensor (heat pump)
T2
Temperature sensor (electric heater)
T3
Temperature sensor (evaporator)
T4
Temperature sensor (air)

Publicidad

Tabla de contenido
loading

Tabla de contenido