Electrical Connection; Chimney Assembly - ROBLIN Ombre 800 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
RECYCLING VERSION AIR OUTLET
To install the hood in recycling version, the optional charcoal
filter kit must be purchased.
• Remove the chimney angle bracket.
• Screw the filter cover onto the air outlet, using four screws 12c
(2.9 x 12.5).
• Fix the air outlet grid 8 on the recirculation air outlet using the
2 screws 12d (2,9 x 9,5) provided.

ELECTRICAL CONNECTION

• Connect the hood to the mains supply.
• Open the upper panel by pressing the A-key (See Part "USE" )
for at least 2 seconds.
• Remove the metal filters (See Part "MAINTENANCE") and
make sure that the connector piece of the supply cable is cor-
rectly inside the hood socket.
Upper exhaust Chimney
• Slightly widen the two sides of the upper chimney and hook
them behind the brackets 7.2.1, making sure that they are well
seated.
• Secure the sides to the brackets using the 4 screws 12c (2,9 x
9,5) supplied.
Lower exhaust Chimney
• Slightly widen the two sides of the chimney and hook them
between the upper chimney and the wall, making sure that they
are well seated.
• Fix the lower part laterally to the hood body using the 2 screws
12c (2,9 x 9,5) supplied.
EN

Chimney assembly

12d
8
12c
16
7.2.1
2.1
2
2.2
12c
12c
9 9

Publicidad

Tabla de contenido
loading

Tabla de contenido