Iec Symbols And Symbol Definitions; Indications For Use; Igo Control Panel - DeVilbiss Healthcare iGo 306DS Manual Del Usuario

Sistema de oxígeno portátil
Ocultar thumbs Ver también para iGo 306DS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13

Iec SYMbolS And SYMbol deFInItIonS

Attention - Consult Instruction Guide
Danger-No Smoking or Naked Flame
Electric Shock Hazard
Alternating Current
Direct Current (DC Power)
Type BF Equipment
Drip Proof Equipment IPX1
Non-protected (ordinary equipment)
IPX0
Follow instructions for use

IndIcAtIonS For uSe

The Model 306 DeVilbiss iGo Portable Oxygen Concentrator System is indicated for the administration of supplemental oxygen. The device is not intended for life support, nor
does it provide any patient monitoring capabilities.
IMPortAnt PArtS (Page 2)
deVilbiss iGo Portable oxygen System (Fig. A-e)
1.
Handle (one on top rear/two on bottom-sides)
2.
Control Panel - Refer to iGo Control Panel below
3.
Power Button - Press and hold the Power On/Off
Button to turn your unit on or off.
4.
Oxygen Outlet - oxygen is dispersed through this
port.
5.
Power Input - Connect either AC or DC power.
iGo control Panel (Fig. 1)
1.
Power Button - turns the system ON or OFF
2. N o Breath Detected in PulseDose Mode Light -- When the iGo is in PulseDose mode and doesn't sense any breathing for 30 seconds, light flashes; audible alert will
beep every 3 seconds when this activates. If a breath is detected during the alert, the alert condition is cleared. If a breath is not detected during the alert, the unit
changes to Continuous Flow mode after 60 seconds of alerting. NOTe–Once the unit changes to Continuous Flow, use the Mode Select Button to change back to
PulseDose.
3.
External Power Present Light/Power Fail Alert
3a. External Power Present Light – Light illuminates when the iGo system is connected to either AC or DC power.
3b. P ower Fail Alert – Audible Alert sounds in conjunction with flashing light for 15 minutes when Power Fail Alert activates. Pressing the Power Button stops the alert.
4.
Oxygen Concentration Lights:
4a. Green Normal Oxygen Light = Normal Operation, Acceptable Oxygen Level; illuminates when your iGo is operating properly.
4b. Yellow Low Oxygen Light = Operating Below an Acceptable Oxygen Level; illuminates when there is a problem with your unit. Refer to Troubleshooting for
instructions
4c. Red Service Required Light = Abnormal Operation/Malfunction, Concentration Below an Acceptable Oxygen Level; illuminates with an audible alert when there is a
problem with your unit. Switch to your reserve oxygen system. Refer to Troubleshooting and/or call your DeVilbiss provider for instructions. Do not attempt any other
maintenance.
5.
Mode Select Button and Flow Indicator Light
5a. Use Mode Select Button to select either PulseDose or Continuous Flow.
5b. Flow Indicator Light pulses with every breath when in PulseDose mode; illuminates continuously when in Continuous Flow mode
6.
Green Flow Rate Setting Lights (1-6) and Flow Rate Setting Buttons
6a. Y our provider has set your prescribed flow rates for both PulseDose and Continuous Flow. Do not change these settings unless it is under the order of your
physician.
6b. I ncrease Flow Rate Setting Button and Decrease Flow Rate Setting Button – use buttons to increase or decrease your flow rate if a change is ordered by your
physician.
7.
Battery Status Gauge and Low Battery Alert – when a Battery is installed, this indicates the charge remaining in battery. All 6 lights illuminate Green when fully charged.
As battery becomes depleted, the top lights will go out. When battery gets to lowest operating level, the lowest light will turn Yellow and one short audible alert will sound.
The lights cycle when battery is being charged.
A-306-1
WEEE Taiwan
Recyclable Li-ion Battery
RBRC Recycle
Power Button
No Breath Detected in PD Mode with
audible alert
External Power Present Indicator (solid
light). Power Fail Alarm (flashing light)
Normal Oxygen
No Naked Flames
The device contains electrical and/or electronic equipment that must be recycled per EU Directive
2012/19/EU - Waste Electrical and Electronic Equipment (WEEE)
6.
Communication Port - This port allows service
personnel to diagnose and monitor iGo
performance. It is not for patient use.
7.
Air Filter
8.
Rating Label (on bottom)
9.
Exhaust Vents (on each side)
10. Cart Connection
11. Battery Bay
Service Required
Flow Indicator
Mode Select (Continuous Flow/PulseDose)
Button
Increase Flow Setting
Decrease Flow Setting
Rechargeable Battery Status Symbol
Low Oxygen
Use no oil or grease
12. Slot in Battery Bay
13. Rechargeable Battery
14. Battery Tabs
15. Battery Latch
16. Battery Contacts
17. AC Adapter
18. DC Adapter
en - 5

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido