Product Description; Motor Pump - Pentair STA-RITE CPS 10 Serie Manual De Instrucciones

Convertidor de frecuencia electrónico
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 84
EN
RS-485 → Communication port
INI
→ INIBIT input: NC external
contact or NO for the START/STOP
command
S.P.
→ External Set Point (EST)
command: NA contact
→ NTC sensor input to control
NTC
temperature
TRASD. → Input 0÷5 Volts for
pressure transducer
→ Positive
+
-
→ Negative
→ Signal
D
CHAPTER 4
FUNCTIONING

4.1 PRODUCT DESCRIPTION

4.1.1 MOTOR PUMP

The system is composed of a motor
pump and an electronic control system
(inverter) that enables the pressure to
be maintained constant in the system,
reducing or increasing the rotation
speed of the pump motor
26
When the system pressure goes
below the threshold set, the module
starts the pump to reset the set
point pressure; the rotation speed of
the pump varies based on the water
request, therefore, greater request
requires greater speed, until the
maximum set pressure is reached
When the request for water decreases,
speed will also reduce until the pump
reaches the minimum speed set and
after which, if there are no further
decreases in pressure
(i.e. new water requests), the pump will
go in stand by until a new cycle begins

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sta-rite cps 20 serie

Tabla de contenido