WARNING The electrical connections in this manual refer exclusively to the NET series control boards. If you are using GULLIVER
with control board 212E or 400RR, please refer to the user manual of those control boards for all the wiring needed to startup the
motor.
5 ELECTRICAL CONNECTIONS FOR 230V MODELS
Execute the wiring following the directions of "Table 1" and diagrams on page 21.
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm in the
open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits
power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure multi pole
disconnection from the power supply, with a contact opening of 3 mm.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
WARNING For reversible models with electronic brake and without NET230N on board, remember to set the parameter P062=3 (electro-
brake output for reversible motors).
1-2
230 V ~ ±10% (50/60 Hz) power supply input
3-4-5
Operator 1 output 230 V ~ max 600W
6-7-8
Operator 2 output 230 V ~ max 600W (if present)
9-10
230 V ~ max 150 W output for open gate warning light (if P052=0) or courtesy light (if P052>1)
11-12
Flashing light output 230 V ~ max 40W
13 (-)
13-14
14 (+)
15-16
17 - N.C.
17-18
18 - Com
19 - N.C.
19-20
20 - Com
21 - N.C.
21-22
22 - Com
23 - N.C.
23-24
24 - Com
25 - N.O.
25-26
26 - Com
27 - N.O.
27-28
28 - Com
29
Aerial signal input
Ground aerial input
30
31-32
24 V ~ power supply output for auxiliary devices 200mA
20
Tabella 1 "collegamento alle morsettiere"
"Boost" output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1), step
by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for electric-lock
power supply via external relay (if P062=4), output for electro-magnets power supply for barriers (ifP062=5)
or temporized output (if P062>5).
Output 24V
max 100mA; by selecting the FL/WL jumper, you can choose the 230 Flash output as a 24V
output (if the jumper is set to FL) or as a Warning light output (if jumper set to WL).
Warning: the output capacity allows to use LED flashing lights only
Input 6 FCC 1. If it intervenes it stops M1 closing. If unused, short circuit.
Input 5 FCA 1. If it intervenes it stops M1 opening. If unused, short circuit.
Input 4 PHOTO 1. When enabled (see parameter P050 in the table), activation of PHOTO
1 provokes: an inversion of direction (during closing), the arrest of the movement (during
opening), prevent the start (gate closed). If unused, short circuit.
Input 3 SAFETY. If activated, it causes the inversion. See P055 and P056 on the parame-
ters table. If unused, short circuit.
Input 2 PED. If activated, it opens motor nr. 1 only.
Input 1 START. In case of intervention it provokes: the operator opening or closing. It may
operate as "inversion" mode (P049=0) or "step by step" mode (P049=1).
.
2