3.4 - ELECTRIC CONNECTION
DANGER
• The power feed line should be provided
with a suitable omni-polar DISCONNECT-
ING SWITCH (automatic thermo-magnetic
switch or differential) placed before the
control unit main switch, with a minimum
contact opening of 3 mm.
• The earthing system should comply with
the local electric regulations in force.
• The electric power cables should comply
with the maximum current required by
the machine.
• The specifications of the electric power
line should correspond to the specifica-
tions of the identification plate and to
those mentioned in the technical speci-
fications table that can be consulted in
the first part of this booklet.
3Ph+PE
L3 L2 L1
3
3Ph+N+PE
L3 L2 L1 N
EN - 14
Before connecting the machine to the
electric line, make sure that the DISCON-
NECTING SWITCH is disconnected (line
not energized).
The disconnecting switch placed in the upper
part of the oven shall be easily to be reached.
In case of two- and three-chamber ovens,
each oven shall be connected with a special
knife switch, it is not possible to connect
more than one oven to one knife switch.
3.4.a - Electric oven connection (Fig.5)
• Remove the cover (1) by undoing the screws (2).
• Connect the cable to the terminal board (3).
• Connect the phases to the terminals L1, L2 and L3,
the neutral wire to the terminal N, the earth to the
terminal T.
• For areas where the automatic load distributor is
present, connect the two 12V power supply wires to
"SAFE" terminals.
• Remount the casing (1).
2
1
2
SUPER TOP
Installation and connections
DANGER
IMPORTANT
DANGER
FIG. 5