Technical Specifications - Lincoln Electric POWERTEC 305C PRO Manual De Instrucciones

Ocultar thumbs Ver también para POWERTEC 305C PRO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.
The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system.
locations, due to conducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-12 provided that the short-circuit power S
at the interface point between the user's supply and the public system. It is the responsibility of the installer or user of
the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is
connected only to a supply with a short circuit power S

Technical Specifications

POWERTEC 305C, 355C & 425C PRO:
Input Voltage
230 / 400V ± 10%
Three Phase
Duty Cycle
(
Based on a 10 min. period
305C PRO:
40%
60%
100%
355C PRO:
40%
60%
100%
425C PRO:
40%
60%
100%
Welding Current Range
305C PRO:
355C PRO:
425C PRO:
Fuse or Circuit Breaker Size
305C PRO:
355C PRO:
425C PRO:
English
There may be potential difficulties in ensuring electromagnetic compatibility in those
POWERTEC 305C PRO:
POWERTEC 355C PRO:
POWERTEC 425C PRO:
Input Power at Rated Output
305C PRO:
355C PRO:
425C PRO:
RATED OUTPUT AT 40°C
)
30A - 280A
30A - 350A
30A - 420A
RECOMMENDED INPUT CABLE AND FUSE SIZES
32A (for 230V) Superlag
20A (for 400V) Superlag
40A (for 230V) Superlag
25A (for 400V) Superlag
50A (for 230V) Superlag
32A (for 400V) Superlag
WARNING
WARNING
S
≥ 1,9MVA
sc
S
≥ 2,2MVA
sc
S
≥ 2,9MVA
sc
greater than or equal to data on the table above.
sc
INPUT
13.5 kVA @ 40% Duty Cycle
17.5 kVA @ 40% Duty Cycle
22.8 kVA @ 40% Duty Cycle
Output Current
280A
230A
175A
350A
285A
220A
420A
345A
265A
OUTPUT RANGE
Maximum Open Circuit Voltage
305C PRO:
355C PRO:
425C PRO:
305C PRO:
355C PRO:
425C PRO:
8
is greater than or equal to:
sc
EMC Group / Class
II / A
II / A
II / A
Output Voltage
28.0 Vdc
25.5 Vdc
22.8 Vdc
31.5 Vdc
28.2 Vdc
25.0 Vdc
35.0 Vdc
31.3 Vdc
27.3 Vdc
46 Vdc
46 Vdc
52 Vdc
Input Power Cable
4 Conductor, 4mm
4 Conductor, 4mm
4 Conductor, 6mm
Frequency
50/60 Hz
2
2
2
English

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Powertec 355c proPowertec 425c pro

Tabla de contenido