IO-Link Data Dictionary
21.10.01.00077/05
IO-Link Implementation
Vendor ID
Device ID
SIO-Mode
Baudrate
Minimum cycle time
Processdata input
Processdata output
Process Data
Process Data In
Number of device which generatetd a condition
monitoring or error event
PD In Byte 0
EPC-Select acknowledged
Device status
PD In Byte 1
EPC value 1
PD In Byte 2
EPC value 2, high-byte
PD In Byte 3
EPC value 2, low-byte
Air saving function (H1) Ejector #1
Part present (H2) Ejector #1
Air saving function (H1) Ejector #2
Part present (H2) Ejector #2
PD In Byte 4
Air saving function (H1) Ejector #3
Part present (H2) Ejector #3
Air saving function (H1) Ejector #4
Part present (H2) Ejector #4
Air saving function (H1) Ejector #5
Part present (H2) Ejector #5
Air saving function (H1) Ejector #6
PD In Byte 5
Part present (H2) Ejector #6
(if available - see PD-In length)
Air saving function (H1) Ejector #7
(for up to 8 ejectors)
Part present (H2) Ejector #7
Air saving function (H1) Ejector #8
Part present (H2) Ejector #8
Air saving function (H1) Ejector #9
Part present (H2) Ejector #9
Air saving function (H1) Ejector #10
PD In Byte 6
Part present (H2) Ejector #10
(if available - see PD-In length)
Air saving function (H1) Ejector #11
(for up to 12 ejectors)
Part present (H2) Ejector #11
Air saving function (H1) Ejector #12
Part present (H2) Ejector #12
Air saving function (H1) Ejector #13
Part present (H2) Ejector #13
PD In Byte 7
Air saving function (H1) Ejector #14
(if available - see PD-In length)
Part present (H2) Ejector #14
(for up to 16 ejectors)
J. Schmalz GmbH
Name
Bit
4 ... 0
5
7 ... 6
7...0
7...0
7...0
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
J. Schmalz GmbH
Johannes-Schmalz-Str.1
D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
schmalz@schmalz.de
IO-Link Version 1.0
234 (0x00EA)
SCTSi with up to 4 ejectors
100265 (0x0187A9)
SCTSi with up to 8 ejectors
100266 (0x0187AA)
SCTSi with up to 12 ejectors
100267 (0x0187AB)
SCTSi with up to 16 ejectors
100268 (0x0187AC)
no
38.4 kBd (COM2)
SCTSi with up to 4 ejectors
4.2 ms
SCTSi with up to 8 ejectors
4.8 ms
SCTSi with up to 12 ejectors
5.4 ms
SCTSi with up to 16 ejectors
6.0 ms
SCTSi with up to 4 ejectors
5 byte
SCTSi with up to 8 ejectors
6 byte
SCTSi with up to 12 ejectors
7 byte
SCTSi with up to 16 ejectors
8 byte
SCTSi with up to 4 ejectors
3 byte
SCTSi with up to 8 ejectors
4 byte
SCTSi with up to 12 ejectors
5 byte
SCTSi with up to 16 ejectors
6 byte
Access
Remark
number of device which generated a warning or error
0:
ro
1 ... 16:
17:
18 ... 31: reserved
Acknowledge that EPC values 1 and 2 have been switched according to
EPC-Select:
ro
0 - EPC-Select = 00
1 - otherwise
00 - [ green] Device is working optimally
01 - [yellow] Device is working, maintenance necessary
ro
10 - [orange] Device is working, but there are warnings in the Control-Unit
11 - [red] Device is not working properly, there are errors in the Control-Unit
EPC value 1 (byte) - holds 8bit value as selected by EPC-Select 0/1
For Device-Select 00:
ro
00 - Error-Byte [ISDU 130.17]
01 - Warning-Byte [ISDU 146.17]
10 - reserved
11 - reserved
For Device-Select 00:
ro
00 - Primary supply voltage (0.1 Volt)
01 - Auxiliary supply voltage (0.1 Volt)
10 - reserved
ro
11 - Total Air cons. of last cycle (0.1 NL)
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
ro
Vacuum is over H1 & not yet under H1-h1
ro
Vacuum is over H2 & not yet under H2-h2
SCTSi series
IO-Link Version 1.1
100261 (0x0187A5)
100262 (0x0187A6)
100263 (0x0187A7)
100264 (0x0187A8)
no warning or error
number of SCPS ejector
Contol-Unit
For Device-Select 01 ... 16:
00 - Error-Byte [ISDU 130.#]
01 - Warning-Byte [ISDU 146.#]
10 - reserved
11 - Leakage of last cycle (mbar/sec)
For Device-Select 01 ... 16:
00 - System vacuum (mbar)
01 - Evacuation time t1 (msec)
10 - Last free-flow vacuum (mbar)
11 - Air consump of last cycle (0.1 NL)
26.09.2020
SCTSi Data Dictionary