IO-Link Data Dictionary
21.10.01.00077/05
144
0x0090
0
Ejectors valve operating counter (erasable)
144
0x0090
1
erasable valve operating counter for ejector #1
144
0x0090
2
erasable valve operating counter for ejector #2
144
0x0090
3
erasable valve operating counter for ejector #3
144
0x0090
4
erasable valve operating counter for ejector #4
144
0x0090
5
erasable valve operating counter for ejector #5
144
0x0090
6
erasable valve operating counter for ejector #6
144
0x0090
7
erasable valve operating counter for ejector #7
144
0x0090
8
erasable valve operating counter for ejector #8
144
0x0090
9
erasable valve operating counter for ejector #9
144
0x0090
10
erasable valve operating counter for ejector #10
erasable valve operating counter for ejector #11
144
0x0090
11
erasable valve operating counter for ejector #12
144
0x0090
12
erasable valve operating counter for ejector #13
144
0x0090
13
erasable valve operating counter for ejector #14
144
0x0090
14
144
0x0090
15
erasable valve operating counter for ejector #15
144
0x0090
16
erasable valve operating counter for ejector #16
Diagnosis
Device Status
32
0x0020
0
Error count
IO-Link Device Status
36
0x0024
0
138
0x008A
1
Extended Device Status - Event Category
138
0x008A
2
Extended Device Status - Event Code
NFC Status
139
0x008B
1
130
0x0082
1
Errors of ejector #1
130
0x0082
2
Errors of ejector #2
130
0x0082
3
Errors of ejector #3
130
0x0082
4
Errors of ejector #4
130
0x0082
5
Errors of ejector #5
Errors of ejector #6
130
0x0082
6
Errors of ejector #7
130
0x0082
7
Errors of ejector #8
130
0x0082
8
Errors of ejector #9
130
0x0082
9
130
0x0082
10
Errors of ejector #10
130
0x0082
11
Errors of ejector #11
130
0x0082
12
Errors of ejector #12
130
0x0082
13
Errors of ejector #13
130
0x0082
14
Errors of ejector #14
130
0x0082
15
Errors of ejector #15
130
0x0082
16
Errors of ejector #16
Errors of Control-Unit
130
0x0082
17
Condition Monitoring [CM]
146
0x0092
0
Condition Monitoring of the system
146
0x0092
1
Condition Monitoring ejector #1
146
0x0092
2
Condition Monitoring ejector #2
146
0x0092
3
Condition Monitoring ejector #3
146
0x0092
4
Condition Monitoring ejector #4
146
0x0092
5
Condition Monitoring ejector #5
146
0x0092
6
Condition Monitoring ejector #6
146
0x0092
7
Condition Monitoring ejector #7
146
0x0092
8
Condition Monitoring ejector #8
146
0x0092
9
Condition Monitoring ejector #9
J. Schmalz GmbH
64 bytes
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
4 bytes
0 - 999 mio
ro
2 bytes
ro
1 byte
ro
1 byte
ro
2 bytes
ro
1 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 byte
ro
2 bytes
ro
17 bytes
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
1byte
0-99
ro
J. Schmalz GmbH
Johannes-Schmalz-Str.1
D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
schmalz@schmalz.de
subindex 0 for access to all ejectors
0
0
0
0
0
0
0
0
number of suction cycles
(since latest erasing)
0
0
0
0
0
0
0
0
Number of errors since last power-up
Status codes according to IO-Link specification V1.1:
0 = device is operating properly
1 = maintenance required
2 = out of specification
3 = functional check
4 = failure
Categorisation of current device status:
0x10: Device is operation properly
0x21: Warning, low
0x22: Warning, high
0x41: Critical condition, low
0x42: Critical condition, high
0x81: Defect/fault, low
0x82: Defect/fault, high
Event Code of current device status (see table below)
Result of last NFC activity:
0x00: data valid, write finished successfully
0x23: write failed: write access locked
0x30: write failed: parameter(s) out of range
0x41: write failed: parameter set inconsistent
0
0xA1: write failed:invalid authorisation
0xA2: NFC not available
0xA3: write failed: invalid data structure
0xA5: write pending
0xA6: NFC internal error
0
0
0
0
0
0
0
For each ejector:
0
Bit 00: Measurement range overrun
0
0
0
0
0
0
0
0
Bit 00: Internal error: data corruption
Bit 01: Internal error: bus fault
Bit 02: Primary voltage too low
Bit 03: Primary voltage too high
0
Bit 04: Secondary voltage too low
Bit 05: Secondary voltage too high
Bit 06: Supply pressure too low or too high
Bit 07-15: reserved
subindex 0 for access to all ejectors and the Control-Unit
0
0
0
0
0
0
0
Bit 0 = valve protection active
Bit 1 = Evacuation time greater than limit
0
Bit 2 = Lekeage rate greater than limit
Bit 3 = H1 not reached in suction cycle
0
Bit 4 = Free flow vacuum too high
SCTSi series
26.09.2020
SCTSi Data Dictionary