Troubleshooting - iTronics IT-01 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Maintenance
After using 5-6 times, or 2 3 days, please clean the product as follows.
Unplug the unit from mains power supply and remove cover.
EN
Pour out any remaining water from the "DRAIN SIDE" of the tank.
Unplug power cord from the base of
Put 1 tablespoon of citric acid in the water tank, add just under 120 ml of
warm water.
Leave for 5 minutes, and then drain solution from the "DRAIN SIDE" of the tank.
Wipe with a soft cloth. Avoid Ultrasonic Vibration plate area, Which can
be gently cleaned with a cotton bud.
1H 2H
3H 4H
Accidental Leakage
In the event of the unit being knocked over or tipped during use, please follow
the steps below to avoid malfunction.
Unplug the unit and remove cover.
Pour any remaining water out of the water tank.
Shake the unit gently to drain any water inside the mechanism, and then
allow drying for at least 24 hours.
-
the
unit.
1H
2H
3H 4H
-8-

Troubleshooting

Experiencing issues with your device? Please check below troubleshooting
tips before contacting us if you wonder whether damage occurred.
SYMPTOM
POSSIBLE CAUSE
Is there any water in the water
tank?
Unit is not
Is there enough water in the
powering on
water tank?
Is the power cord connected
properly?
Not enough water?
Too much water ?
No mist or
Dirt on the ultrasonic plate?
abnormal mist
Cover and inner cover are not
installed properly?
Dirt on the air suction port
at the base?
Cover and inner cover are not
installed properly?
Water leakage
Has the inner cover shifted?
from product
Low temperature or high
humidity?
Disposal
Electrical and electronic components must not be disposed of
with the domestic waste. Once the product reaches the end of
its service life, dispose of it and its components separately in
accordance with the local valid regulations for disposal.
SOLUTION
Add water to tank.
When there is no water or a little amount
of water in the water tank, the power
supply will automatically and immediately
turn off after pressing the MIST button.
Disconnect the adapter, check cables
and re-connect carefully.
Add water to tank.
When the water reaches above the max,
the mist will be abnormal.
Clean the water tank. (Please refer to
the Maintenance Section)
Fix the cover and inner cover because
the mist cannot reach to the FOG
NOZZLE without right installation.
If there is dirt on the air suction port,
the airflow will be restricted and then
mist cannot be blown out.
Fix the cover and inner cover.
The produced mist cannot reach to FOG
NOZZLE and will cause water droplets if
the cover and inner cover shifted.
Under these conditions, the mist may
condense quickly into water droplets.
-9-
EN