3
6
3 TECHNICAL SPECIFICATIONS
ENG
Level indicator description
Level probe
Led display
2
1
7
5
3
4
Circular led display
Digital display
5a
6
7
1 probe head:
the electronic card that makes the probe work is installed in this part
2 electrical connection:
to supply power to the probe.
3 locknut:
tighten this nut from the outside of the tank to fix the probe into place.
4 probe:
this pipe is the part of the probe that, inside the tank, comes into contact with the liquid and measures the
quantity.
5-5a LED display:
this display may be round (5a) or linear (5). It displays the quantity of liquid present in the tank using a
series of lit LEDs.
6 digital display:
this display shows the quantity of liquid present in the tank in number form. This value can also be displayed
graphically with a linear scale (in the upper part of the display).
7 electrical connection cables:
connect the power cable to the tractor power supply and to the probe cables.
24
U s e
&
M a i n t e n a n c e
M a n u a l