bearing roll presses the wire exactly into the groove.
6. Press selector switch on for "wire inching" Press and hold until wire is visible at end
of torch.
7. Tightly connect the gas hose, which comes from the back of the machine to the
brass nipple of supplied regulator, adjust argon regulator to deliver the required litres
per minute.
8. Adjust the welding voltage adjustment knob and wire feeding speed adjustment knob
according to practical needs to get the desired welding voltage and welding current.
9. Press the welding torch switch, and welding can be carried out.
Installation of TIG welding
4. Turn the power source on and select TIG function through the MMA/MIG/TIG
selector
5. Set the welding current in relation to the electrode to be welded.
6. Connection of output cables
Two sockets are available on this welding machine. For TIG welding the TIG torch
should generally be connected to the negative socket, while the work piece should
be connected to the positive socket.
Tips on using gasless wire
When using gasless wire is may be required to change the polarity of the arc. This
can be done simply by reversing the cables inside wire feed cabinet
Gas wire = Positive torch – Negative work (machine is set as standard)
Gasless wire = Negative torch – Positive earth