Operation
OPERATING PROCEDURE –

NORMAL OPERATION

1. Remove cap (A) and inspect test
cell (B) to be sure that it is clean
and empty.
2. Press ON-OFF button (C) to turn
on tester. The display (D) will
show ALWAYS AVERAGE 3 TESTS
for approximately
7 seconds, then will show
CORN.
3. When CORN is displayed, fill the
test cell (B) even to the top of the
cell with sample to be tested.
4. (For Initial Test Only) Before
tightening pressure cap, turn on
tester and allow to warm up for
30 seconds before
attempting first test.
5. Replace cap (A) and tighten until
pressure-indicator screw (F) is flush
with the top of cap (A). (Use Finger-
Flush test as illustrated.)
6. Immediately press TEST button
(G). The words TESTING will be
displayed for about 10 seconds,
while the tester compensates for
temperature. The moisture % and temperature will then be displayed for about 10
seconds.
7. The tester will then return to displaying CORN. Empty the test cell and refill with a
fresh sample and test again.
NOTE:
6
Take at least three readings of new corn from the
sample collected and average the results.
A - Cap
B - Test Cell
C - ON-OFF Button
D - Display
E - Select Arrows
F - Pressure-Indicator Screw
G - Test Button