Light Emitting Diodes (Led) On Charger; Connecting Battery To Power Tool - Stihl AR 900 Manual De Instrucciones

Ocultar thumbs Ver también para AR 900:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 70
English
2)
During operation: Power tool
switches itself off – allow battery to
cool down for a while.
3)
Electromagnetic interference or
fault. Acoustic signal can be heard
as a rapid series of sounds lasting
several seconds – see also
"Acoustic Signal". Disconnect
battery from power tool, take it off
your back, observe battery and
contact your STIHL servicing dealer
immediately – see also
"Troubleshooting".
4)
Electromagnetic interference or
fault. Take the adapter out of the
power tool and refit it. Switch on the
power tool – if the light emitting
diodes still flash, the power tool is
faulty and must be checked by a
STIHL servicing dealer.
34
Light Emitting Diodes (LED)
on Charger
1
The light emitting diode (1) on charger
glows continuously green or flashes red.
Green continuous light ...
... may mean the following:
The battery
is being charged
is too hot and must cool down
before it is charged
See also "Light Emitting Diodes (LEDs)
on Battery".
The green light emitting diode on the
charger goes off as soon as the battery
is fully charged.
Red flashing light ...
... may mean the following:
No electrical contact between
battery and charger – remove and
refit the adapter
Faulty battery – see also "Light
Emitting Diodes (LEDs) on Battery".
Charger faulty – have checked by
STIHL servicing dealer.
Connecting Battery to Power
Tool
A factory-new battery is not fully
charged.
Recommendation: Fully charge the
battery before using it for the first time.
If necessary, remove the cover from
N
the power tool's battery
compartment before fitting the
adapter, i.e. depress both locking
levers to unlock and remove the
cover.
Insert adapter
Insert the adapter (1) in the power
N
tool – the adapter slides into the
compartment – press it down
carefully until it snaps into position –
the adapter must be flush with the
top of the housing.
AR 900