MOUNTING

The base unit is intended to be wall mounted or fitted in a 19" rack. The base unit must be mounted
vertically to allow the free flow of ventilation and allow heat to escape. The base unit must be fixed with
steel screws Ø 6 mm. The screws are not included in a package. Where 2 or more base units are mounted
above each other it is important to leave minimum 10-15 cm free space between the base units to ensure
normal ventilation. In case when ventilation panel 400.024 (see chapter ACCESSORIES) is used connect
grounding bus, data bus and RF cables at first.
Note: the total weight of a fully equipped UC380 is approximately 10 kg.
the base unit is
delivered with fixing
brackets in the forward
position for assembling
into a 19" rack

VENTILATION

Mount in the vertical position only. In warm climatic conditions additional cooling may be necessary.
19" rack or wall installation
Figure 3.

BASE UNIT UC380

Figure 1.
minimum
gap 10 cm
for wall mounting,
reverse the fixing
brackets to the
position as shown
19" rack installation with ventilation panel
ventilation
panel 400.024
see chapter
ACCESSORIES