Introduction
The YELLOW JACKET
™
and AccuProbe
II Hand-held Leak Detectors
detect all HCFC refrigerants such as R-22 and
R-124. The ultra-sensitive long life sensor
with Solid Electrolyte Sensor Technology also
detects the more current, difficult-to-detect
refrigerants such as R-134a, R-1234yf,
R-404A, R-407C and R-410A (see page 7
for a more complete chart of detectable
refrigerants).
The ACCUPROBE UV is equipped with the
unique digital SmartAlarm
the first digital leak size indicator in a hand-
held heated sensor leak detector. This feature
takes the guesswork out of whether or not to
repair a small leak. Unlike the more traditional
LED bar graphs that copy or mimic the audio
alarm signal, the SmartAlarm digital leak size
indicator measures, registers and displays the
leak size independently from both the audio
alarm and the sensitivity level.
Features
Advanced digital SmartAlarm™ leak size
x
indicator
(AccuProbe
Flashing visual alarm indicator at probe end
x
(AccuProbe
UV)
Audio mute button
x
Operates on 4 AA alkaline batteries
x
(AccuProbe UV
3 LED UV light system that works with
x
395-415nm wavelength leak tracing dyes
(AccuProbe
UV)
Microcontroller technology
x
Ultra-high sensitivity to detect leaks as
x
small as 0.06 oz (1.7g)/yr. of R-134a/
R-1234yf and 0.03 oz (0.9g)/yr. of R-22.
See insert sheet for certified ratings.
2
®
™
AccuProbe
™
LED display –
UV)
(AccuProbe
UV)
can also use AC power)
UV
The ACCUPROBE UV also features a 3 LED
UV light system that works with 395-415nm
wavelength leak tracing dyes. The sleek, ergo-
nomic design of these YELLOW JACKET
leak detectors makes them easy to use in close
areas and extendable into hard-to-reach areas.
When finding leaks, it is important to note that
the AccuProbe responds to changes in concen-
tration of refrigerant. For this reason, the
detector will stop alarming even though it is
held at or near the source of the leak and will
not alarm again until the detector senses a
change in concentration. To verify the exact
location of the source of the leak, always
move the probe away from the area of the leak
briefly to allow the sensor to reset at a lower
concentration, and then bring it back again
until the exact location of the leak source has
been verified.
Automatic calibration and reset to ambient
x
Detects HFC, HCFC, CFC and HFO
x
refrigerants (see page 7)
Long life stable sensor utilizing Solid
x
Electrolyte Sensor technology
3 selectable sensitivity level settings
x
Sleek ergonomic design
x
Low battery indicator
x
Temp Range 24° to 125°F (-4° to 52°C)
x
Humidity 0 to 95% RH noncondensing
x
CE Marked
x
True mechanical pump
x