Now, switch on the operating voltage of the unit by pressing the arrow keys.
Setup
Enter the Setup menu and set the Values for lower / upper limit and range. Choose the desired temper-
ature sensor. See also chapter 5 Set-up Menu on page 7
3
General information
The BH-510 is a compact, feature rich, intuitive FAT Temperature Controller for wall-mounting. FAT
stands for Fast-Adaptive-Tuning. A novel algorithm permanently adjusts the control parameters to the
control process. The common adjustment of PID controllers or the execution of an auto tuning proce-
dure is obsolete.
The self-optimizing controller logic leads to an efficient adaption to any closed-loop controlled pass and
quickly reaching adjustment between set-point temperature and actual (temperature) value.
All functions are shown inside the display and can be easily reached and set via the buttons on the
control panel.
The BH-510 is equipped with a long-life Hybrid-Relay designed for low thermal losses inside the hous-
ing. An additional Safety-Relay underlines the high standard in terms of safety and efficiency of the BH-
510.
A multi-colored LED is signaling the different operating modes, easy viewable in the distance.
The electronics is protected against overcurrent and high thermal load.
4
Control panel
4.1

Overview of functions


Enter set up menu: simultaneous pressing Enter Button
Change Set-Point Temperature: Press (hold) Up


Failure notes can be reset by pressing enter button
Controller On/ Off: simultaneous pressing Up Button

4.2
Standard display information
Set-point temperature:
Temperature maintained by the controller
Actual (temperature) value:
Actual temperature measured by connected temperature sensor
Temperature above
Thermometer Icon informs:
tolerance at set-point temperature
Heater-Icon
visible:
Heater on
®
© BriskHeat
Corporation
BH-510 Operation Manual
Display  
Up  / Down  Bu ons  
Status LED   
Enter Bu on   
Back Bu on  
and Back Button
or Down
Button
and Down Button
for several seconds
/ beneath
/ in between
range of
®
. All rights reserved.
5
4.3
Status monitor (3-color-LED)
After connecting to power supply, the controller starts with a self-test: white LED on for 1 sec. Self-test
successfully completed and controller starts heating: green LED on for 0.3 sec.
If a failure would be detected a default signal will show up: see 4.4 Fault Detection.
The heat-up phase continuous until the set-point temperature has been reached: blue LED on/off with a
frequency of 1 Hz
Set-point temperature reached:
The Controller works at set-point temperature inside the tolerance-band set by the user: green LED
permanent on
Temperature monitor:
The temperature during operation, is permanently under control. The LED remains green at set-point
temperature in-between the band of tolerance. Above and below this temperature range the LED starts
to blink with a frequency of 1Hz. Blue signals too low and red too high temperatures.
4.4

Fault detection

From start and during operation the controller is permanently checking PCB temperature, power sup-
ply, sensor break and failure of the relays. If any failure occurs the controller stops heating (stand-by)
Additionally the error occurs in the display. Failure notes can be reset by pressing enter button
the failure note cannot be reset by this procedure, the occurring problem has to be solved and the
controller reconnected to power supply to restart the controller.
Fast blinking signal of failures with a frequency of 4 Hz.
1.
Device failure:
2.
Sensor failure
®
© BriskHeat
Corporation
BH-510 Operation Manual
. If
®
. All rights reserved.
6