MANUAL INSTRUCCIONES
AEROTERMOS RMO y RMOB
MANUAL INSTRUCCIONES
MANUEL D'INSTALLATION
INSTALLATION MANUAL
RMOB13,5
C/. Ca n'Alzamora, 34-36 - 08191 RUBÍ
Tels. +34 93 586 00 45
E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com
NTC - 9802
Pag 1
Ed 11
29/04/05
RMO4
RMO4A
RMO6
RMOB6
RMO9
RMOB9
RMO13,5
RMO18
RMOB18
(Barcelona)
ESPAÑA
Fax
+34 93 586 00 48

Publicidad

loading

Resumen de contenidos para Electricfor RMO4

  • Página 1 RMO4 RMO4A RMO6 RMOB6 RMO9 RMOB9 RMO13,5 RMOB13,5 RMO18 RMOB18 MANUAL INSTRUCCIONES MANUEL D'INSTALLATION INSTALLATION MANUAL C/. Ca n’Alzamora, 34-36 - 08191 RUBÍ (Barcelona) ESPAÑA Tels. +34 93 586 00 45 +34 93 586 00 48 E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com...
  • Página 2 Se recomienda comprobar el estado y funcionamiento del aparato al desembalarlo, cualquier defecto de origen está amparado por la garantía. Electricfor, S.A. elude cualquier responsabilidad sobre el mal funcionamiento o averías causadas por uso inadecuado del aparato o por una instalación no acorde a las presentes instrucciones .
  • Página 3: Recomendaciones De Seguridad

    21° a 75 ° Zona de barrido Sweeping zone SUELO Longitud de barrido / Sweeping length C/. Ca n’Alzamora, 34-36 - 08191 RUBÍ (Barcelona) ESPAÑA Tels. +34 93 586 00 45 +34 93 586 00 48 E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com...
  • Página 4 A - Placa cambio de tensión. Los bornes 3 y 4 se suministran puenteados. En caso Los RMO4 se suministran conectados a ~230 V. de que usted desee instalar su RMO a través de un ter- B - Registro de conexiones.
  • Página 5: Funcionamiento

    En todas las instalaciones de interconexión de los aparatos RMO será conveniente comprobar la concordancia de fases de los bornes de entrada de los aerotermos, R, S, T y N a fin de no efectuar cortocircuitos. C/. Ca n’Alzamora, 34-36 - 08191 RUBÍ (Barcelona) ESPAÑA Tels. +34 93 586 00 45 +34 93 586 00 48 E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com...
  • Página 6 The state and functioning of the equipment should be checked on unpacking. Any source defects are covered by the guarantee. Electricfor, S.A. takes no responsibility for malfunction, faults, or accidents caused by incorrect use of the equipment, or by an installation, which does not comply with these instructions.
  • Página 7 21° a 75 ° Zona de barrido Sweeping zone Longitud de barrido / Sweeping length SUELO C/. Ca n’Alzamora, 34-36 - 08191 RUBÍ (Barcelona) ESPAÑA Tels. +34 93 586 00 45 +34 93 586 00 48 E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com...
  • Página 8 SUPPLY CONNECTIONS OF RMO UNITS A- Voltage change board Terminals 3 and 4 are supplied wired together. In the The RMO4 are supplied connected to 230V event that you wish to install your RMO through a room B- Connection inputs...
  • Página 9 In all installations of interconnected RMO units, it will be helpful to check the correspondence of phases of air heaterinput terminals R, S, T, and N, in order to avoid causing short-circuits. C/. Ca n’Alzamora, 34-36 - 08191 RUBÍ (Barcelona) ESPAÑA Tels. +34 93 586 00 45 +34 93 586 00 48 E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com...
  • Página 10 Il est recommandé de vérifier l'état et le fonctionnement de l'appareil lors du déballage, tout défaut d'origine est sous garantie. Electricfor, S.A. décline toute responsabilité concernant le mauvais fonctionnement, les anomalies ou les accidents dus à une utilisation inadéquate de l'appareil ou à...
  • Página 11: Recommandations De Sécurité

    21° a 75 ° Zona de barrido Sweeping zone SUELO Longitud de barrido / Sweeping length C/. Ca n’Alzamora, 34-36 - 08191 RUBÍ (Barcelona) ESPAÑA Tels. +34 93 586 00 45 +34 93 586 00 48 E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com...
  • Página 12 CONNEXION AU CIRCUIT DES APPAREILS RMO PERATURE A- Plaque de changement de tension. Les RMO4 sont livrés pour une connexion de ~230 V. Les bornes 3 et 4 sont livrées shuntées. Si vous dési- B- Boîtier de connexions. Les RMO4A sont livrés pour une connexion de 2 ~400 V.
  • Página 13 Sur toutes les installations d'interconnexion des appareils RMO, il conviendrait de vérifier la concordance des phases des bornes d'entrée des aéro- thermes et des phases R, S, T et N afin d'éviter des courts-circuits. C/. Ca n’Alzamora, 34-36 - 08191 RUBÍ (Barcelona) ESPAÑA Tels. +34 93 586 00 45 +34 93 586 00 48 E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com...