6. Electrical work
1
CHECK
ON/OFF
TEMP
E
3
C,D
FAN
AUTO STOP
MODE
VANE
AUTO START
CHECK
LOUVER
h
F
A
TEST RUN
min
B
SET
RESET
CLOCK
Fig. 6-10
6.3.2 Function setting on the remote controller
Refer to the indoor unit operation manual.
Function table
Select unit number 00
Mode
Power failure automatic recovery
Indoor temperature detecting
LOSSNAY connectivity
Power voltage
Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller])
Mode
Filter sign
Fan speed
*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
2
CHECK
CHECK
4
CHECK
CHECK
Settings
Not available
Available
Indoor unit operating average
Set by indoor unit's remote controller
Remote controller's internal sensor
Not Supported
Supported (indoor unit is not equipped with outdoor-air inlet)
Supported (indoor unit is equipped with outdoor-air inlet)
240 V
220 V, 230 V
Settings
100Hr
2500Hr
No filter sign indicator
Silent
Standard
High ceiling
2) For wireless remote controller (Fig. 6-10)
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.
1 Go to the function select mode
CHECK
button F twice continuously.
Press the
(Start this operation from the status of remote controller display turned off.)
is lighted and "00" blinks.
CHECK
Press the temp
button C once to set "50". Direct the wireless remote controller
toward the receiver of the indoor unit and press the
2 Setting the unit number
Press the temp
button C and D to set the unit number "00". Direct the
wireless remote controller toward the receiver of the indoor unit and press the
button B.
3 Selecting a mode
Enter 04 to change the power voltage setting using the
Direct the wireless remote controller toward the receiver of the indoor unit and
h
button A.
press the
Current setting number:
1 = 1 beep (one second)
2 = 2 beeps (one second each)
3 = 3 beeps (one second each)
4 Selecting the setting number
C and
D buttons to change the power voltage setting to 01 (240 V).
Use the
Direct the wireless remote controller toward the sensor of the indoor unit and press
h
the
button A.
5 To select multiple functions continuously
Repeat steps 3 and 4 to change multiple function settings continuously.
6 Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and press
button E.
the
Note:
Whenever changes are made to the function settings after installation or
maintenance, be sure to record the changes with a mark in the "Setting"
column of the Function table.
Mode no.
Setting no.
01
*1
02
03
04
Mode no.
Setting no.
07
08
h
button A.
C and
D buttons.
Initial setting
setting
1
*2
2
*2
1
2
3
1
2
3
1
2
Initial setting
setting
1
2
3
1
–
2
3
–
13
min