0 - AUTOMATIC MODE
closed
open
closing
opening
stopped during closing by STOP
stopped during opening by STOP
1 - 4-STEP
closed
open
closing
opening
stopped during closing by STOP
stopped during opening by STOP
2 - SUPER AUTOMATIC
closed
open
closing
opening
stopped during closing by STOP closes
stopped during opening by STOP closes
3 - SEMI-AUTOMATIC with STOP
closed
open
closing
opening
stopped during closing by STOP closes
stopped during opening by STOP closes
4 - STEP-BY-STEP
closed
open
closing
opening
stopped during closing by STOP closes
stopped during opening by STOP closes
5 - MANNED
closed
open
closing
opening
stopped during closing by STOP closes
stopped during opening by STOP closes
6 - TIMER
START
STOP
Closing safety
1
opens
locks
-
3
-
locks
locks
2
re-opens locks
re-opens
2
-
locks
-
closes
-
-
closes
-
-
START
STOP
Closing safety
1
opens
locks
-
5
3
locks
locks
locks
2
re-opens locks
re-opens
2
-
locks
-
closes
-
-
closes
-
-
START
STOP
Closing safety
1
opens
locks
-
1
3
closes
locks
locks
2
re-opens locks
re-opens
2
re-closes locks
-
-
-
-
-
START
STOP
Closing safety
1
opens
locks
-
3
closes
locks
locks
2
re-opens locks
re-opens
2
2
locks
locks
-
-
-
-
-
START
STOP
Closing safety
1
opens
locks
-
3
closes
locks
locks
8
2
locks
locks
re-opens
2
2
locks
locks
-
-
-
-
-
START
STOP
Closing safety
pressed+held
1
opens
locks
-
3
closes
locks
locks
8
2
locks
locks
re-opens
2
2
locks
locks
-
-
-
-
-
- while START is enabled closing is inhibited -
- responses to pulses/signals are the same as for AUTOMATIC MODE -
- 31 -
Pulse/signal
Opening safety edge
1
locks
4
-
-
reverses and locks
-
-
Pulse/signal
Opening safety edge
1
locks
4
-
-
reverses and locks
-
-
Pulse/signal
Opening safety edge
1
locks
4
-
-
reverses and locks
-
-
Pulse/signal
Opening safety edge
1
locks
9
-
-
reverses and locks
-
-
Pulse/signal
Opening safety edge
1
locks
9
-
-
reverses and locks
-
-
Pulse/signal
Opening safety edge
1
locks
9
-
-
reverses and locks
-
-
Operating logic
Opening photocell
Obstacle detection
1
locks
-
6
locks
-
7
locks
re-opens
7
locks
re-opens
-
-
-
-
Opening photocell
Obstacle detection
1
locks
-
6
locks
-
7
locks
re-opens
7
locks
re-opens
-
-
-
-
Opening photocell
Obstacle detection
1
locks
-
6
locks
-
7
locks
re-opens
7
locks
re-opens
-
-
-
-
Opening photocell
Obstacle detection
1
locks
-
9
locks
-
7
locks
re-opens
7
locks
re-opens
-
-
-
-
Opening photocell
Obstacle detection
1
locks
-
9
locks
-
7
locks
re-opens
7
locks
re-opens
-
-
-
-
Opening photocell
Obstacle detection
1
locks
-
9
locks
-
7
locks
re-opens
7
locks
re-opens
-
-
-
-
1
2
1
2
1
2
1
2
1
2
1
2