6.5 ASSEMBLY DIAGRAM
Assembly must be carried out by qualified
personnel.
1) Seal
2) Covering in ceramic bre or rock wool with
aluminium foil, or ue pipe with double wall.
3) External air intake below replace level
4) Heat recovery grid, x it on the highest point of
the cladding.
5) Flame-retardant counter hood and load-
bearing structure
6) Screen the parts in wood with a re-retardant
material
7) Minimum distance of 1 cm between cladding
and Fireplace
8) If there are ammable materials or structures
on the back of the rebox, they must be at a
minimum distance of 20 cm.
9) The minimum clearance between the stove and
ignitable materials must be 20 cm.
The minimum distance from combustible
materials must be 20 cm.
To ensure correct installation, the smoke pipe
between the replace and ue must be airtight,
sealing all the joints.
If the fireplace is installed with a flue that
has already been used with other replaces,
it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts
deposited on the inside from catching re.
Improper installation may compromise the
safety of the unit.
It must be possible for quali ed personnel to
access the inside of the stove when it is not in
operation.
The cladding must be in reproof material and
it must not have any removable parts, so that
electrically powered and moving parts are not
accessible by the user.
Do not place ammable objects or materials
in the radiation area of the hearth, and in any
case not less than 1 m.
6.6 PELLETS LOADING
The pellets are loaded via a hatch to be tted to the
hood of the enclosure and connected to the stove
with the optional accessory equipment. Make sure
to follow the installation instructions included with
the kit.
Do not use the stove removal system to load the
pellet tank.
Do not use non-original accessories.
48
INSTALLATION
1
2
3
Pellets falling outside the tank can compromise the
proper operation of the stove and may ignite and
cause re.
The pellet loading pipe must be used solely as a
chute for loading the tank and not as an extension to
the tank itself; do not ll the tank beyond its normal
capacity (without the pipe).
00 477 3370 - 09/2014 - PN - Italy
4
5
6
7
Fig. 6.5.1