mENU
Enables or disables Man present function.
On: Man Present operation.
htr
The OPEN/CLOSE buttons must be held down during the whole manoeuvre.
Off: Automatic operation.
The calculation of residual operating time is activated or deactivated in the event of
partial operations:
On: Calculation of deactivated time. In case of partial operations, the operating time
is reset. The following operation restarts for the entire time preset by parameter TM1/
not
TM2.
Off: Calculation of activated time. In case of partial operations, the operating time
is stored in memory and then subtracted from the TM1/TM2 parameter value in the
following operation.
Select the 1/2 motors operating mode:
On: only one motor (motor 1) active. Function to be used in the following cases:
- for single motor, to connect M1:4-5-6.
1mot
- for two syncronized motors (for instance overhead door), to connect M1:4-5-6 and
M2:7-8-9. You need to regulate the parameters related to the motor 1, the limit
switch entries M2 are disarmed (not activate).
Off: Both motors operating.
The Encoder is enabled or disabled. See section " TYPES OF INSTALLATIONS"
ENC
On: Encoder enabled – The anti-crash sensor is activated.
Off: Encoder disabled – The anti-crash sensor is deactivated.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Cvar
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vdc.
Before each opening manoeuvre the power supply is interrupted for the time set by
mloc
the parameter TLOC.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vdc for the time set by the pa-
rameter TLOC.
The check for integrity of TRIAC is enabled or disabled.
TRK
On: Activated check: if TRAC is faulty, the motor does not start.
Off: the TRIAC is not checked.
The test of photocells to PHOT O input is enabled or disabled.
On: Test is enabled. If the test is negative, no operation is performed. See Fig.1
TST1
"PHOTO TEST".
Off: Test is disabled.
The test of photocells to PHOT C input is enabled or disabled.
On: Test is enabled. If the test is negative, no operation is performed. See Fig.1
TST2
"PHOTO TEST".
Off: Test is disabled.
On: AUX2 Output, preset as open gate light. See "SCA" figure.
Light switched on with open gate, fast flashing during closure, slow flashing during
2CH
opening, light off with closed gate.
Off: AUX2 output, preset as second radio channel of the built-in receiver.
The thrust function in the closing phase is activated or deactivated by this logic. With
SLD logic only: ON
On: the operation in the closing phase is carried out at normal speed during the
BB
last second (braking is disabled). In this way, a better hooking of the electric lock is
performed.
Off: disabled function.
The automatic switching is activated/deactivated in Service Man mode.
On: If the sensitive edge remains activated for at least 10 seconds with open or clo-
Horm
sed gate, the control unit automatically switches to Service man mode.
Off: Disabled function.
The remote storage of the radio transmitter codes is enabled or disabled (see par.
REMOTE LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
16
FUNCTION
Settable values
mEmO
ON-OFF-(Default)
(OFF)
(ON)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)