Beninca BRAINY Manual De Instrucciones página 17

Ocultar thumbs Ver también para BRAINY:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
mENU
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the step-by-step
function.
PP
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the second radio
channel.
2Ch
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the pedestrian
opening function (see TPED parameter).
ped
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be erased from memory.
CLR
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
The memory of the receiver is entirely erased. Confirmation for the operation is asked.
RTR
By selecting this function, the receiver waits for (Push) the GPM key to be pressed again to confirm the operation.
At end of erasing, the OK message is displayed
Note: The transmitters are stored in an EPROM memory (Fig.1 -U11), which can be removed and repositioned in a new control
unit, it required.
mENU
The control unit performs a series of operations for the learning of the door leaf stroke.
Initially, both leaves are moved to closed position, then, after one, or both leaves, has carried out some opening
auto
and closing operations with different speeds, the working OK is displayed on the control unit. If this operation is
not successful, the message ERR is displayed. After checking both cables and the presence of obstacles again,
repeat the operation.
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
RES
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again
resets the control unit.
Displays the number of complete cycles (open+close) carried out by the automation.
NMAN
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last
4. Example <PG> 0012 >>> <PG> 3456: made 123.456 cycles.
It allows to type in an access protection code to the programming of the control unit.
A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-
E-F.
The default value is 0000 (four zeros) and shows the absence of a protection code.
While typing in the code, this operation can be cancelled at any moment by pressing keys + and – simultaneously.
Once the password is typed in, it is possible to act on the control unit by entering and exiting the programming
mode for around 10 minutes in order to allow adjustments and tests on functions.
By replacing the 0000 code with any other code, the protection of the control unit is enabled, thus preventing the
access to any other menu. If a protection code is to be typed in, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is shown, also in the case a protection code has been previously typed in.
- the value of the flashing character can be changed with keys + and -.
code
- press OK to confirm the flashing character, then confirm the following one.
- after typing in the 4 characters, a confirmation message "CONF" appears.
- after a few seconds, the code 0000 appears again
- the previously stored protection code must be reconfirmed in order to avoid any accidental typing in.
If the code corresponds to the previous one, a confirmation message "OK" appears.
The control unit automatically exits the programming phase. To gain access to the Menus again, the stored protec-
tion code must be typed in.
ImPORTANT: TAKE NOTE of the protection code and KEEP IT IN A SAFE PLACE for future maintenance
operations. To remove the code from a protected control unit, it is sufficient to reset the code to the 0000
default value.
IF YOU LOOSE ThE CODE, PLEASE CONTACT ThE AUThORISED SERVICE CENTER FOR ThE TOTAL RESET
OF ThE CONTROL UNIT.
FUNCTION
FUNCTION
17

Publicidad

Tabla de contenido
loading

Tabla de contenido