The torque applied to motor 2 during braking in the closing phase is adjusted *
The intervention threshold of the anti-crashing device (Encoder) during the phase at nor-
SeaU
mal speed is adjusted.*
0:Off-1:minimum sensitivity - 99: maximum sensitivity
The intervention threshold of the anti-crashing device (Encoder) during braking is ad-
SEAR
justed *.
0:Off-1:minimum sensitivity - 99: maximum sensitivity
This parameter is enabled only for motors equipped with Encoder.
tinc
The encoder inhibition is regulated near the opening and closing mechanical stoppers.
1: minimum distance – 250: maximum distance
** WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN A DANGER.
COMPLY WITH REGULATIONS IN FORCE!
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
Off: condominium function disabled.
IbL
On: condominium function enabled. The step-by-step impulse or transmitter impulse has
no effect during the opening phase.
During the TCA phase, the PP controls are enabled or disabled.
IbCA
On: PP controls are disabled.
Off: PP controls are enabled.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the intervention of
SCL
the photocell causes automatic closing after 3 s. Active only with TCA:ON.
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enables or disables the inversion stroke function
On: Function enabled. Before each opening manoeuvre the control unit orders a manoeu-
HAM
vre of 2s in the opposite direction to facilitate the release of the electric lock.
Off: Function disabled.
Enables or disables the block maintaining function.
Recommended for hydraulic motors to keep the leaf resting against the mechanical stop
block.
BLC
On: Block maintaining function enabled. Every 2 hours the control unit makes a closing
manoeuvre with a duration of about 3s to keep the leaf in contact.
Off: Block maintaining function disabled.
Enables or disables starting torque function.
On: Starting torque enabled. At the start of each manoeuvre for 2s the motor operates at
SPN
maximum torque.
Off: Starting torque disabled.
Selects the operating mode of the blinking light during the time TCA
LTCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
Enables or disables Man present function.
On: Man Present operation.
htr
The OPEN/CLOSE buttons must be held down during the whole manoeuvre.
Off: Automatic operation.
16
LOGIC (LOG)
FUNCTION
1-99-(70%)
0-99-(0%)
0-99-(0%)
1-250-(250)
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)