Technical Data - Beninca BRAINY Manual De Instrucciones

Ocultar thumbs Ver también para BRAINY:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
All parameters must be preset manually. In particular, values of TM1/TM2 must be some seconds higher than the actual operating
time.
AUTOMATIC SYSTEM WITH ELECTROMECHANIC LIMIT SWITCHES AND WITHOUT ENCODER
In this operating mode, the NOT=OFF logics and the ENC=OFF logics must be preset.
All parameters must be preset manually. In particular, values of TM1/TM2 must be some seconds higher than the actual operating
time.
Some messages that are displayed in the event of malfunctions are shown hereunder:
Error, motor 1 encoder
Enc1
Error, motor 2 encoder
Enc2
Error, motor 1 obstacle
Amp1
Error, motor 2 obstacle
Amp2
Error, check motor 1 circuit
Err1
Error, check motor 2 circuit
Err2
Error, check actiation relay
Err3
Error, check PHOTA photocell
Err4
Error, check PHOTC photocell
Err5
Error, activated sensitive edge (during self-set)
Err6
Error, activated stop (during self-test)
Err7
Error, activated input (during self-test)
Err8
In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches,
control and safety) can be displayed. One segment of the display is linked to each input.
In the event of failure it switches on according to the following scheme.

TECHNICAL DATA

Mains power supply
Output, Motor
Motor maximum power
Output, power supply of accessories
Protection level
Operating temperature
Radio receiver
No. of codes storable in memory
20
ERROR MESAGES
Check the connection to motor 1 encoder
Check the connection to motor 2 encoder
Check the presence of obstacles on the motor 1 leaf stroke
Check the presence of obstacles on the motor 2 leaf stroke
Check connections to motor 1
Check connections to motor 2
Ask for technical assistance
Check connections, alignment of PHOT A photocell or obstacle
present.
Check connections, alignment of PHOT C photocell or obstacle
present.
During self-setting, the safety edge was activated.
During self-setting, the STOP input was activated.
During self-setting, a Start/Pedestrian/Open/Close input was acti-
vated.
DIAGNOSTICS
230 VAC 50/60 Hz (115VAC 50/60 Hz for BRAINY 115)
1/2 motor, 230Vac (1/2 motors 115 Vac for BRAINY 115)
600W + 600W
24VAC 1A max.
IP54
-20°C / +60°C
433,92 MHz, incorporated and configurable
64
SWO-M1
SWO-M2
SWC-M1
SWC-M2
P.P.
PED
OPEN
PHOT-O
STOP
PHOT-C
DAS
CLOSE

Publicidad

Tabla de contenido
loading

Tabla de contenido