Cleaning And Maintenance - HQ-Power VDP250MHS18FL2 Manual Del Usuario

Ocultar thumbs Ver también para VDP250MHS18FL2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

How to turn the controller line from 3-pins into 5-pins (plug and socket)
d. DMX512 Chain with Termination
e. DMX512 Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start
address is the channel number from which the device starts to "listen" to the DMX controller. Enter the correct
number and read it from the display located on the base of the VDP250MHS18FL2.
You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the VDP250MHS18FL2s will "listen" to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you
set different addresses, each device will "listen" to a separate channel number. Changing the settings of one channel
will only affect the device in question.
In the case of the 16-channel VDP250MHS18FL2, you will have to set the start address of the first
VDP250MHS18FL2 to 1, the second VDP250MHS18FL2 to 17 (1 + 16), the third to 33 (17 + 16) and so on.

6. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts apart from the lamp and the fuse.
8. Contact your dealer for spare parts if necessary.
VDP250MHS18FL2_v2
A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120 resistor between pins 2 and 3, which is then plugged into
the XLR output socket of the last device in the chain.
Please see illustrations.
8
HQPOWER

Publicidad

Tabla de contenido
loading

Tabla de contenido