Periodic Maintenance - ENAR QP Manual De Instrucciones

Reglas vibrantes fijas y extensibles
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.- The permitted heating of the cable according to VDE standard (minimum transversal section table required).
Therefore, the section chosen is equal to 4 mm
two verifications.
SECTION LINE mm
25
16
10
6
4
2,5
1,5
0
1000
NOMINAL INTENSITY X LINE LENGTH (A m)

4.3 PERIODIC MAINTENANCE

MAINTENANCE WITH PETROL ENGINE
1.- Daily (8 hours).
Clean the motor and the beams, check the bolts & nuts, check and fill the motor's reservoir with oil.
2.- Weekly (50 hours).
Change the motor oil (first 20 hours), clean the sparking plugs and the air filter.
3.- Monthly (200 hours).
en
Clean the oil filter, clean and adjust the sparks plugs.
4.- Every 500 hours.
Clean and set the carburettor, clean the cylinder's head, set the valves.
5.- Always use original parts by every maintenance operation.
6.- The safety fittings have to be checked after every maintenance.
7.- Every 12 months or more frequently, the screed has to be sent to an authorized workshop for
service according to the intensity of the usage.
8.- Do not fill the fuel tank while smoking or near any other potential source of danger.
Lock the petrol admission key when filling, use unleaded gas, clean the gas spelt.
9.- Idle speed of the motor must not exceed 3.000 rpm (standard set).
By every maintenance operation, the idle speed of the engine has to be checked and adjusted at
3.000 rpm. See the engine's manual to set the engine speed, starting and stopping.
10.-
MAINTENANCE WITH ELECTRIC MOTOR
1.-
2.-
3.-
4.-
5.-
6.-
7.-
8.-
service according to the intensity of the usage.
9.-
8
I.e.: For 10 A, according to table for 15 A or less, the section is of 1 mm
2
115 V
230 V
2000
3000
4000
5000
Check the oil level in the exciter reservoir every 100 hours (10W 40 non foaming).
The operating of the electric parts must be done by a specialist.
During the maintenance, make sure that the device is disconnected from the power source.
Always use original parts by every maintenance operation.
The bearings of the motor do not need a periodic maintenance.
Inspect the plug, the socket as well as the cables every 100 Hours.
Periodically clean the housing of the motor to prevent an overheating.
The safety fittings have to be checked after every maintenance.
Every 12 months or more frequently the screed has to be sent to an authorized workshop for
Re-screw the nuts and bolts daily.
2
, always chose the highest transversal section of the
Minimun section according VDE rules
2
Line (mm
)
380 V
1
1,5
2,5
4
6
10
16
6000
25
EXTENSIBLE DOUBLE BEAM VIBRATING SCREEDS
2
.
Maximum (A)
Max fuse (A)
15
10
18
10/3-16/1-
26
20
34
25
44
35
61
50
82
63
108
80

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

QpmQghQgr

Tabla de contenido