12. Reset
12.1 Simple reset
A simple reset is required to configure the FT 200 / FT 200 CAP furniture terminal with the
MDU 110 data transfer unit.
Prerequisites:
1. Press the reset button.
A brief acoustic signal is heard.
12.2 Complete reset
A complete reset is required after losing the programming or clearing key card. The system
then has to be reconfigured
A complete reset clears all data on the programming and clearing key card as well as the
locking authorisations for the user keys. The factory settings of the FT 200 / FT 200 CAP
furniture terminal are restored.
Prerequisites:
1. Press the reset button.
A brief acoustic signal is heard.
A tool to actuate the reset button, such as a thin pen/pencil or
opened out paper clip
< 1s
2. Press and hold the reset button until a long
acoustic signal is heard.
6. Start-up.
A tool to actuate the reset button, such as a thin pen/pencil or
opened out paper clip
< 1s
2. Press and hold the reset button until two long
acoustic signals are heard.
The lock on parametrisation with the
MDU 110 data transfer unit is disabled.
All data and access rights are cleared.
> 1s
2x > 1s
39