10
3
Illustration
1 ON/OFF switch
2 Rotational direction switch
3 Mechanical two-speed selector
4 Torque adjustment ring
5 Battery locking
6 Battery
7 Battery charging unit
Accessories illustrated or described are not always
included as standard delivery items.
4

Technical Data

Electronic battery-driven rotary
screwdriver
Article number
Right/Left rotation
No-load speed
1st Gear
2nd Gear
Screwing into wood up to max.
Drilling into steel up to
Drilling into wood up to
Spindle thread
Drill chuck span
Mechanical torque selection
Max. torque
Weight with battery
Rechargeable Battery A132
Article number
(Spare parts no. 46416)
Type
Rated voltage
Capacity
Number of cells
Operating temperature range
Weight
Battery charging unit
Article number
(Spare parts no. 30858)
Input voltage
Output voltage
Charging current/time
Weight
5
Measured values determined according to
EN 50 260.
Sound pressure level:
Sound power level:
Work place emission value:
For operation, noise protection measures are
required.
The acceleration measured is usually less
than 2.5 m/s
6
MAX 132/s
The rated voltage of the battery must agree with the
value on the machine.
12 04 2401
– The batteries are not charged. They therefore have
to be charged before use.
– A new battery develops full power only after it has
–1
0–450 min
been subjected to approx. 5 charging and dis-
–1
charging cycles.
0–1500 min
6 mm
– The maximum service life of the batteries is
10 mm
attained if you charge these at an ambient temper-
ature of between +5 °C and max. +45 °C.
16 mm
– If the battery is not within the permitted loading
3/8" UNF
temperature range (approx. +5 °C and +45 °C)
1–10 mm
charging time is extended by the cooling or warm-
in 7 stages
up time.
to approx. 7 Nm
– Important! Batteries will discharge even if the tool is
18 Nm
not used. They should therefore be re-charged reg-
approx. 1.75 kg
ularly.
Or better still – connect the battery to the mains
charger which will automatically switch to mainte-
98 02 4701
nance charging after the battery has been fully
charged. This is particularly useful for maintenance
NiCd
and for the optimal operational readiness of the
13.2 V
batteries.
1.5 Ah
– Do not leave the battery in the charger if the latter
11
is not in operating condition.
+5 °C ... +45 °C
0.8 kg
MSL 60
98 03 3401
230 V ~
13.2 V
approx. 1.65 A /
approx. 60 min
approx. 1.3 kg

Noise/vibration information

2
.

Charging the batteries

MAX 132/s
63 + 3 dB (A)
76 + 3 dB (A)
66 + 3 dB (A).

Publicidad