3
Installation
Product must be installed by a qualified person
in accordance with the regulations in force. The
manu-facturer shall not be held responsible for
damages arising from procedures carried out by
unauthorized persons which may also void the
warranty.
C
Preparation of location and electrical
and gas installation for the product
is under customer's responsibility.
A
WARNING: The product must be
installed in accordance with all local
gas and/or electrical regulations.
WARNING: Prior to installation,
A
visually check if the product has any
defects on it. If so, do not have it
installed. Damaged products cause
risks for your safety.
3.1 Before installation
The hob is designed for installation into commer-
cially available work tops. A safety distance must
be left GLASS between the appliance and the
kitchen walls and furniture. See figure (values in
mm).
• It can also be used in a free standing position.
Allow a minimum distance of 750 mm above the
hob surface.
• (*) If a cooker hood is to be installed above the
cooker, refer to cooker hood manufacturer' in-
structions regarding installation height (min
650 mm)
• Remove packaging materials and transport
locks.
• Surfaces, synthetic laminates and adhesives
used must be heat resistant (100 °C minimum).
• The worktop must be aligned and fixed horizon-
tally.
• Cut aperture for the hob in worktop as per in-
stallation dimensions.
Built-In Hob / User Manual
3.2 Room ventilation
All rooms require an openable window, or
equvalent, and some rooms will require a per-
manent vent as well.
The air for combustion is taken from the room
air and the exhaust gases are emitted directly
into the room.
Good room ventilation is essential for safe op-
eration of your appliance.
3.2.1 Rooms with doors and/or
windows which open directly to the
outer environment
The doors and/or windows that open direct-
ly to the outer environment must have a total
ventilation opening of the dimensions spec-
ified in the table below which is based on the
total gas power of the appliance (total gas pow-
er consumption of the appliance is shown in the
technical specification table of this user manu-
al). If the doors and/or windows do not have a
total ventilation opening corresponding to the
total gas consumption of the appliance as spec-
ified in the table below, then there must defi-
nitely be an additional fixed ventilation opening
in the room to ensure that the total minimum
ventilation requirements for the total gas con-
sumption of the appliance is achieved. The
fixed ventilation opening can include openings
for existing airbricks, extraction hood ducting
opening dimension etc.
13 / EN