Mediclinics E85 Manual De Instalación Y Utilizacion página 9

Secador de manos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
INSTALLATION
Dismantling for installation
• Unscrew the two lockscrews
with the special SANIFLOW wrench.
• Remove the cover, taking care
not to knock the equipment.
• Handle the cover with care.
Mounting
• Concealed wiring mounting (A).
• Put the wiring through before tightening
up the base on the wall.
• Use the template provided for wall fixing.
• Drill 4 holes with diameter of 8 mm. (5/16"),
taking care to clean the dust.
• Screw the base firmly to the wall using
a 6-7 mm. (1/4") flat-ended screwdriver.
Machine must be handled only
by an autorized techinician.
WARNING: When dismantle the cover,
electrical live and basic insulated parts
are accesible.
The automatic model has proximity sensors mounted on the cover, close to the air outlet.Therefore
the sensor has to be connected during the installation. Once the base fixed to the wall, after the
follow-up of all the steps shown in the sections "dismantling for installation" and "mounting" the
procedure is as follows:
1. Inside the cover you can find the sensors wire fixed by a subjection. Detach it from its provisional
subjection by taking care of not to pull the wire (A).
2. Hold the cover without tightening the wire. Plug it into electronic plate from the base, into the
connector card wich you can find in the middle and right side of same. There is only a position that
fits smooth. Do not force the connection (B).
3. When mounting the cover, take care that the sensors wire remains under the black evolute of air
ejection. For the assembly, insert the cover into the base and screw the two lockscrews underneath.
-9-
www.mediclinics.com

Publicidad

Tabla de contenido
loading

Tabla de contenido