Main screens

During normal operation of the device, the display may show information on:
1 min inactivity
1. Instantaneous active power measurement; "P -" is indicated if the power is produced*
2. Active energy consumed measurement; max. 5 digits *
3. Active energy produced measurement; max. 5 digits *
4. Status of remote loads: "OFF"; "ON" if the load is powered but without a power measurement;
power in kW if powered and measured (received directly from the remote load)
5. As in point 4 (NB: L0 = load 10)
6. Status of local load: "ON" if NO contact is closed/NC open; vice versa "OFF"
7. Power threshold status: "OFF"; "ON" based on the status of their activation for the monitoring
function
8. As in point 7
Use the
and
inactivity on the device, the absorbed power screen (1) is displayed again.
* NB: meters only show the five least significant digits of the current value on the screen (max. value
99999 kWh, two digits at the top and three at the bottom).

Resetting energy meters

Both active energy meters can be reset using the dedicated reset function.
To reset the active energy consumed meters:
1. From the energy consumed screen, press the "SET" button key for at least 5 seconds until
the confirmation screen is displayed, where the text "rES" will flash in place of the value
2. Press the "SET" button key to reset the meter and display the energy consumed screen
again with the figure reset OR press the
The same procedure must be followed to reset the energy produced meter, taking care to repeat the
steps starting from the active energy produced screen.
button keys to move between the various displays. After about 60 seconds of
or
button key to cancel the reset operation
pag. 19