Operating The C Com 16

USING THE ENHANCER

ENHANCER
13
The C Com 16's ENHANCER switch can be engaged to activate the EFR (Enhanced Frequency Recovery) circuit.
By engaging the ENHANCER, the C Com 16 EFR restores the high frequency content that can be lost when high
gain reduction is applied. The C Com 16 EFR achieves this by adding back the high-end of the original signal in
an amount that is equal to the amount of gain reduction.
Follow the section above, "SETTING UP THE C Com 16" for
normalizing the controls and run a signal such as a CD
through the C Com 16.
Set the PROGRAM switch to 13; STEREO COMP.
Press the BYPASS switch to the IN position so that the green
LED is on.
Turn up the SENSITIVITY control until you reach 12 to 24 dB of gain reduction.
Engage the ENHANCER switch and listen to how the high end is restored.
USING THE KEY EXT I/O INSERT JACK

KEY INSERT

14
The C com 16 features a KEY insert jack which allows you to externally control the
compressors trigger signal. Using the KEY insert jack, you can patch in an external
processor to affect the compressors trigger. A typical application for external process-
ing of the KEY signal is inserting a graphic equalizer to filter. The KEY insert jack is
internally wired so the TIP is the KEY SEND and the RING is the KEY RETURN.
RIGHT
12
13
-10
+4
14