Installation - SCHOLTES SCHG 640 GH Manual De Instrucciones

Encimera
Ocultar thumbs Ver también para SCHG 640 GH:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Installation

! Before operating your new appliance please read this instruction booklet
carefully. It contains important information for safe use, installation and care
of the appliance.
! Please keep these operating instructions for future reference. Pass them on
to possible new owners of the appliance.
Positioning
! Keep packaging material out of the reach of children. It can become a choking
or suffocation hazard (see Precautions and tips).
! The appliance must be installed by a qualified professional according to the
instructions provided. Incorrect installation may cause harm to people and
animals or may damage property.
! This unit may be installed and used only in permanently ventilated rooms in
accordance with with current national regulations. The following requirements
must be observed:
• The room must be equipped with an air extraction system that expels
any combustion fumes. This may consist of a hood or an electric fan that
automatically starts each time the appliance is switched on.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
• The room must also allow proper air circulation, as air is needed for
combustion to occur normally. The flow of air must not be less than 2 m
per kW of installed power.
The air circulation system may take air directly
from the outside by means of a pipe with an
inner cross section of at least 100 cm
opening must not be vulnerable to any type
of blockages.
A
Examples of
ventilation holes
for comburant air.
The system can also provide the air needed
Adjacent
Room to be
for combustion indirectly, i.e. from adjacent
Room
Vented
rooms fitted with air circulation tubes as
described above. However, these rooms must
not be communal rooms, bedrooms or rooms
that may present a fire hazard.
Enlarging the ventilation slot
between window and floor.
• Liquid petroleum gas sinks to the floor as it
is heavier than air. Therefore, rooms containing LPG cylinders must also
be equipped with vents to allow gas to escape in the event of a leak. As
a result LPG cylinders, whether partially or completely full, must not be
installed or stored in rooms or storage areas that are below ground level
(cellars, etc.). It is advisable to keep only the cylinder being used in the
room, positioned so that it is not subject to heat produced by external
sources (ovens, fireplaces, stoves, etc. ) which could raise the temperature
of the cylinder above 50°C.
Fitting the appliance
The following precautions must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller than the top of the
hob must be at least 600 mm from the edge of the hob.
• Hoods must be installed according to their relative installation instruction
manuals and at a minimum distance of 650 mm from the hob (see figure).
• Place the wall cabinets adjacent to the hood at a minimum height of 420
mm from the hob (see figure).
600mm min.
• The installation cavity should have the dimensions indicated in the figure.
Fastening hooks are provided, allowing you to fasten the hob to tops that
are between 20 and 40 mm thick. To ensure the hob is securely fastened
to the top, we recommend you use all the hooks provided.
• Before fastening the cooktop in place, position the seal (supplied) along
Directly to
the Outside
the perimeter of the countertop, as shown in the figure.
/h
3
; the
2
Hook fastening diagram
Hooking position
for top H=20mm
Hooking position
for top H=40mm
If the hob is installed beneath a wall cabinet,
the latter must be situated at a minimum of
700 mm above the hob.
55
mm
555
mm
Hooking position
for top H=30mm
Front
Back
GB
17