2.2. Water connection
• Connect the cold water entrance (marked in blue) to the water cooler,
and the hot water entrance (marked in red) to the network
• Follow the connection instructions from the drawing.
2.3. Electrical connection
• Connect the water dispenser to a compatible current socket as indicated in
the label, which indicates the voltage and frequency.
• It is recommended that the electrical socket has earth return.
• For greater security, it is recommended that the electrical socket has
electrical protection, by means of a fuse.
Do not manipulate the water meter inside without disconnecting
the electrical plug. The device can only be manipulated by experts
and authorized personnel.
• If the water meter does not ignite, verify the protection fuse located in the
electrical plug. If the fuse is defective, replace it by a 2 Amperes fuse.
4