5.
Press ON key to begin dosing. The amount of emptied water is dis-
played.
6.
Press OFF button to stop water dosing procedure. If ON key is pressed
the procedure will begin again.
7.
When you have 10 litres in your container, adjust the quantity on the
display with the UP and Down buttons.
8.
Press Up and DOWN button at the same time to confirm the volume.
9.
During 2 seconds the screen will display the new value of pulses calcu-
lated by the dispenser
3.3. Manual tuning pulses for litres.
1.
Before switching ON the equipment hold simultaneously the 'UP and
'DOWN' buttons.
2.
Move Power SWITCH to position I. The programmed pulses will display.
3.
To adapt the pulses per litre, press UP and DOWN keys. The factory
value is programmed to 70 pulses per litre. If you put a higher number
the meter will let more water pass. If you put a lower number, the mixer
will let less water pass.
4.
Press Up and DOWN button at the same time to confirm parameters.
4. ELECTROVALVE WARNING FAILURE
1.
The dispenser will stop if it detects liquid passage by the electrovalve
during stop. It will activate the acoustic alarm signal and will display the
error message -E -.
2.
To deactivate the alarm signal, press the OFF key.
3.
Disconnect the water meter from the power supply and repair the elec-
troválve as soon as possible.
SINMAG EUROPE BVBA
ENG
7