Maintenance; Maintenance Table - Airpress HL 360/50 compact Manual De Instrucciones

Tabla de contenido

Publicidad

6.0 MAINTENANCE

Before carrying out any maintenance jobs it is obligatory to stop the
machine, disconnect it from the power mains and make sure that the tank is
pressure free by opening the condensation draintap (10).
1. After the first 50 operating hours and then every 250 operation hours the oil should
be refreshed. Turn off the oil drain plug (90) and also remove the filler cap (6).
Collect the oil. If the oil does not come out any longer, switch on the drainplug
again and refill the oil (through fillercap) until the oil has reached the correct level.
The right oil level is on the red circle on the oil leveler (8).
Always respect the regulations in force for disposing of old oil!
2. Regularly drain condensation water. The draintap is situated at the bottom of the
tank (10). Draining with pressure in the tank is the easiest way. Some
compressors have an aftercooler with its own drainplug. Also from this device the
condensationwater should be drained regularly.
Condensate must be disposed of in conformity with the local regulations in
force (not in the sewer!).
As an alternative you can place an oil/water separator.
3. The oil level should also be checked regularly. For the right oil level see point 1. If
necessary refill with compressor oil, order No 12491 (0,6 l) or order No 12492 (1
l). Checking daily can prevent a lot of troubles!
Use oil of the same type as that already in the machine; do not mix different
types of oil!
4. The air filter element (3) should be cleaned or changed regularly. This change
depends on the amount of fouling and should be done more often in dusty
situations and less often in a clean situation. For cleaning the filterelement, take
out the filtercontainer with the filter. Then clean the filter by blowing off the dust.
Note: Regular maintenance of your compressor will increase durability and
reliability.

MAINTENANCE TABLE

works
draining
condensation water
check
oil level
clean
air filter
refresh oil (first time
after 50 hours)
All manuals and user guides at all-guides.com
daily
weekly
18
every
250 hours 1000 hours
every

Publicidad