LEGRAND Wattstopper EOSW-101 Instrucciones De Instalación página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MOUNTING AND WIRING
After connecting the load and line wires, secure the
EOSW to the wallbox using the two screws that are
provided. Please, do not force or overtorque unit with
torque screw driver. To do so may damage the unit.
EOSW-101
Neutral
Line
Black
Ground
Green
EOSW-102
Neutral
Line
Black
Ground
Green
Red
Primary
Load
Red
Primary
Load
Brown
Secondary
Load
AIR GAP SWITCH
FLUORESCENT LOAD SERVICING
IMPORTANT NOTE: ALWAYS ACTIVATE THE
AIRGAP SWITCH ON THE EOSW BEFORE
The EOSW receivers provide an airgap switch for safety in case
of "service" on the receiver and/or load is required, such as
changing a lamp. The airgap must be activated to completely
disconnect the load when it is off.
DISCONNECTING THE LOADS
To prevent leakage current to the load:
Press down on the Airgap button as shown to activate the Air Gap
• The load(s) will turn OFF. The load switch buttons will not
turn on when pressed
Press the Airgap Release button (left side) to deactivate the
airgap switch
• Green LEDs will briefly flash, blue LEDs will come on at low
level
• Wait approximately 5 seconds and then press the load
buttons to turn the loads back on.
Air Gap
Release Button
Press down to deactivate
2
SERVICING
Air Gap
Air Gap Button
Press down to activate

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wattstopper eosw-102

Tabla de contenido