Environmental conditions
Climate
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
(9.81 m/s
Transport
Operation
Mounting conditions
Mounting place
Mounting position
Free space
Mounting position
Standard
Variant
EDK94AZMS DE/EN/FR/ES/IT 8.0
General data and operating conditions
IEC/EN 60721−3−1
1K3 (−25 ... +60 °C)
IEC/EN 60721−3−2
2K3 (−25 ... +70 °C)
IEC/EN 60721−3−3
3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C:
Device size 1 ... 7: 2.5 %/°C
Device size 8S ... 10: 1 %/°C
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
EN 61800−5−1
Degree of pollution 2
2
= 1 g)
IEC/EN 60721−3−2
2M2
EN 61800−2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
200 ... 500 Hz: acceleration resistant up to 15 m/s
Germanischer
5 ... 13.2 Hz: amplitude ±1 mm
Lloyd
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
IEC/EN 60068−2−6
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 1 g
In the control cabinet
Vertically
The required free space results from the mounting
position and the specifications of the standard device.
Footprint mounting; standard device is screwed on
the filter
Side−by−side mounting; filter is directly screwed to the
left of the standard device (
installation)
l
Technical data
^
Mechanical
4
2
2
39