Mechanical installation
Side−by−side mounting − device size I
E94AZxS0044
E94AZxS0104
E94AZxS0294
3. Under limited space conditions, filter and mounting base can be connected
electrically. (^ 49)
4. Screw the filter onto the mounting plate.
– Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
– If further devices are to be mounted directly adjacent on the right−hand side of the
filter, do not tighten the screws fully before all devices are mounted and aligned.
– Tightening torque: 3.4 Nm (30 lb−in).
I
Tip!
Under limited space conditions, filter and mounting base can be connected
electrically when step 2 has been carried out.
Side−by−side mounting − device size I
Mounting steps
How to proceed for side−by−side mounting:
1. Prepare M5 threaded holes on the mounting plate, for instance according to the
mounting grid.
– Always use all mounting points specified.
2. Mount the filter on the prepared mounting plate to the left of the mounting base.
– Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
– If further devices are to be mounted directly adjacent on the right−hand side of the
filter, do not tighten the screws fully before all devices are mounted and aligned.
– Tightening torque: 3.4 Nm (30 lb−in).
46
Screws
2 x M5x20
2 x M5x25
l
Tightening torque
3.4 Nm (30 lb−in)
EDK94AZMS DE/EN/FR/ES/IT 8.0